Redback® Proudly Made In Australia
12
Redback®
Programmable Control System
3.7 SERIAL and IR CONTROL with FIFTEEN LOW POWER and TWO HIGH CURRENT RELAYS
This configuration expands the standard setup to provide serial and IR control with 15 low power output relays and two high
current output relays.
The A 6500 Wall Plate is connected to the A 6505 Serial Hub via a CAT5e/6 cable. 24V DC power is connected to the A
6505 by a plugpack with a 2.1mm jack or through the euro block terminals. The A 6505 in turn powers the A 6500 Wall
Plate through the Cat5e/6 cable and powers the A 6510 and A 6515 by running a cable from the 24DC In terminals of the
A 6505 to the 24V In terminals of the A 6510 and A 6515.
The A 6505 Serial Hub can then be connected to up to two RS232 or RS485 controlled devices. IR control of multiple devices
is available through the IR repeater output and a total of seventeen relay outputs enable control of devices with a closing
contact. The relay contacts on the A 6505 are rated at 2A maximum and a set of normally open and normally closed contacts
are available for each relay. The relay contacts on the A 6510 are rated at 1A maximum with normally open contacts only.
The relay contacts on the A 6515 are rated at 16A maximum with a set of normally open and normally closed contacts for
each relay.
Fig 3.7
System Configurations
Redback® A 6500
Redback® A 6505
24V DC PLUGPACK
(MINIMUM 1A)
(Cat5/6 Cable 50m Maximum)
A 1052 IR REPEATER
RS232/
RS485
RS232/
RS485
RELAY CONTROLLED
DEVICES
Relay OUT
1 2 3
RS485-1
RS232-1
IR
RS485-2
RS232-2
TO A 6500
RELAY CONTROLLED DEVICES
(CONTACTS MAX 16A)
Relay OUT
RS485
RS232
TO A 6500
TO REDBACK
®
DEVICES
2 1
Redback® A 6515
Redback® A 6510
Relay OUT
RS485
RS232
1
2
3
4
5
6
7
8
9
10
11
12
TO A 6500
TO REDBACK
®
DEVICES
RELAY CONTROLLED DEVICES