www.redbackaudio.com.au
Redback® Proudly Made In Australia
6
Redback® A 4498
Network Connection Pack
UART Settings
Once the login has been accepted, the “Administrator Setting” page should be open. Navigate to the “UART” page via the
navigation tab on the left.
The “Mode” & “Baudrate” settings need to be changed to “RS485” & “115200” respectively.
Once complete, the screen should look as shown in figure 10.
Fig 10. UART Settings
Press the “Update” button on the bottom of the page. The page will flash briefly as it saves the settings and refreshes. To
confim the change has been made, navigate to another page, and then back to the UART page, and the settings should
have been retained.
TCP Settings
Next, navigate to the “TCP Mode” page. Set the following fields to ‘0’: “Client mode inactive timeout” and “Server mode
protect timeout”.
The default communication port used is 23. If a different port is required, change it now. If unsure if a different port is
needed, leave it as default.
Once complete, the screen should look as follows:
Fig 11. TCP Settings
Press the “Update” button on the bottom of the page. These settings require the unit be restarted, so press the “Reset”
button, and then the “ok” button. This will take you back to the login page, so log in again and confirm the settings have
been saved.