background image

19

19

WARRANTY

Limited Warranty

For full warranty terms and conditions, visit the link below or refer to the contact details applicable to 
your region. 

Australia, New Zealand
www.redarc.com.au/warranty

REDARC Electronics Pty Ltd
23 Brodie Road (North),
Lonsdale SA 5160
Australia

North America
www.redarcelectronics.com/warranty

REDARC Corporation
c/o Shallco, Inc.
308 Component Dr.
Smithfield, NC 27577
USA

Australia  

1300 REDARC (1300 733 272)

New Zealand

 

+64 9 222 1024

UK and Europe

 

 

+44 (0)20 3930 8109

USA

 

+1 (704) 247 5150

Canada

 

+1 (604) 260 5512

Mexico

 

+52 (558) 526 2898

Summary of Contents for SRC0001

Page 1: ...Cables Value Pack SRC0001 SRC0002 SRC0003 SRC0006 SRC0008 SRC0009 SRC0010 SRC0011 SRC0012 SRC0016 SRC0017 SRC0018 SRC0019 SRPA20 VP SRC0001 CK ...

Page 2: ...ounted to all types of vehicles including but not limited to 4x4 Vehicles RVs Caravans are subject to high wind and vibration forces when driving Solar panels must be securely attached to the vehicle in accordance with all local and national safety standards In addition the solar mount manufacturer s instructions must be adhered to or may be required to be exceeded to comply with local and nationa...

Page 3: ...old water for at least 10 minutes and seek medical assistance immediately CONTENTS REDARC SOLAR CABLES AND VALUE PACK 2 WARNING AND SAFETY INSTRUCTIONS 2 1 SRC0001 5m 16 4ft MC4 TO BARE WIRE CONNECTOR 4 2 SRC0002 10m 32 8ft MC4 TO BARE WIRE CONNECTOR 5 3 SRC0003 1 5m 4 9ft MC4 TO BARE WIRE CONNECTOR 6 4 SRC0006 300mm 11 8 MC4 Y CONNECTORS 7 5 SRC0008 1 5m 5ft ANDERSON TO ANDERSON CABLE 8 6 SRC0009...

Page 4: ...mm 16 4 ft 3 9 Part Number SRC0001 Connector MC4 bare wire Conductor Tinned Cooper Current Rating 1 30 A Conductor size AWG 11 Ø2 3 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Sheath black Fuse Type N A Fuse Rating N A 1 Current rating applies when cable is fully extended Use of cable in coiled state is not recommended ...

Page 5: ... mm 32 8 ft 3 9 Part Number SRC0002 Connector MC4 bare wire Conductor Tinned Cooper Current Rating 1 30 A Conductor size AWG 11 Ø2 3 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Sheath black Fuse Type N A Fuse Rating N A 1 Current rating applies when cable is fully extended Use of cable in coiled state is not recommended ...

Page 6: ...00 mm 4 9 ft 3 9 Part Number SRC0003 Connector MC4 bare wire Conductor Tinned Cooper Current Rating 1 30 A Conductor size AWG 11 Ø2 3 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Sheath black Fuse Type N A Fuse Rating N A 1 Current rating applies when cable is fully extended Use of cable in coiled state is not recommended ...

Page 7: ...mm 4 100 mm 4 Specifications for MC4 Y Connectors Length 300 mm 30 mm 11 8 1 2 Part Number SRC0006 Connectors MC4 Y Conductor Tinned Cooper Current Rating 1 30 A Conductor size AWG 11 Ø2 3 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Sheath black Fuse Type N A Fuse Rating N A ...

Page 8: ...0008 Connector Anderson SB 50 Conductor Bare Copper Current Rating 1 50 A Conductor size AWG 11 Ø2 3 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Positive lead red Negative lead black Sheath black Fuse Type N A Fuse Rating N A 1 Current rating applies when cable is fully extended Use of cable in coiled state is not recommended ...

Page 9: ...ber SRC0009 Connector Anderson SB 50 battery clip Conductor Bare Copper Current Rating 1 30 A Conductor size AWG 11 Ø2 3 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Positive lead red Negative lead black Sheath black Fuse Type MIDI Fuse Rating 40 A 1 Current rating applies when cable is fully extended Use of cable in coiled state is not recommended ...

Page 10: ...Part Number SRC0010 Connector Anderson SB 50 battery terminal Conductor Bare Copper Current Rating 1 30 A Conductor size AWG 6 Ø4 1 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Positive lead red Negative lead black Sheath black Fuse Type MIDI Fuse Rating 40 A 1 Current rating applies when cable is fully extended Use of cable in coiled state is not recommended ...

Page 11: ...nderson to Anderson Connector Length 300 mm 10 mm 1 ft 0 4 Part Number SRC0011 Connector Anderson SB 50 Conductor Bare Copper Current Rating 40 A Conductor size AWG 11 Ø2 3 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Positive lead red Negative lead black Sheath black Fuse Type N A Fuse Rating N A ...

Page 12: ... to Anderson Connector Length 300 mm 10 mm 1 ft 0 4 Part Number SRC0012 Connector Anderson SB 50 Conductor Bare Copper Current Rating 40 A Conductor size AWG 11 Ø2 3 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Positive lead red Negative lead black Sheath black Fuse Type N A Fuse Rating N A ...

Page 13: ... Number SRC0016 Connector Anderson SB 50 bare wire Conductor Bare Copper Current Rating 1 40 A Conductor size AWG 10 Ø2 6 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Positive lead red Negative lead black Sheath black Fuse Type N A Fuse Rating N A 1 Current rating applies when cable is fully extended Use of cable in coiled state is not recommended ...

Page 14: ...2 Part Number SRC0017 Connector Anderson SB 50 MC4 Conductor Bare Copper Current Rating 1 30 A Conductor size AWG 10 Ø2 6 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Sheath black Fuse Type N A Fuse Rating N A 1 Current rating applies when cable is fully extended Use of cable in coiled state is not recommended ...

Page 15: ...mber SRC0018 Connector Anderson SB 50 Conductor Bare Copper Current Rating 1 40 A Conductor size AWG 10 Ø2 6 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Positive red Negative black Sheath black Fuse Type N A Fuse Rating N A 1 Current rating applies when cable is fully extended Use of cable in coiled state is not recommended ...

Page 16: ...1 2 Connector Anderson SB 50 Conductor Bare Copper Current Rating 1 30 A Conductor size AWG 10 Ø2 6 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Positive red Negative black Sheath black Fuse Type N A Fuse Rating N A 1 Current rating applies when cable is fully extended Use of cable in coiled state is not recommended ...

Page 17: ...le plug and play set up of the system The included cables allow the panels to be positioned up to 5 m from the regulator Value Pack Contents 1 SRPA0240 20 A Solar Regulator 2 SRC0018 5 m Anderson to Anderson cable 3 SRC0009 1 5 m Anderson to battery clip cable 2 1 3 15 SRC0001 CK MC4 CONNECTOR KIT The SRC001 CK includes a male and female MC4 connector ...

Page 18: ... the Solar Panels is connected directly to the regulator Refer to the manufacturer s instructions The SRC0009 Battery clip cable is intended for a portable short term connection and is not to be left connected permanently 16 2 Fuse Protection Fuse protection is required for wire and component protection in case of short circuit Fuses must be fitted as close as possible to the battery positive term...

Page 19: ...edarc com au warranty REDARC Electronics Pty Ltd 23 Brodie Road North Lonsdale SA 5160 Australia North America www redarcelectronics com warranty REDARC Corporation c o Shallco Inc 308 Component Dr Smithfield NC 27577 USA Australia 1300 REDARC 1300 733 272 New Zealand 64 9 222 1024 UK and Europe 44 0 20 3930 8109 USA 1 704 247 5150 Canada 1 604 260 5512 Mexico 52 558 526 2898 ...

Page 20: ...il Australia and other Global regions power redarc com au www redarc com au 1300 REDARC 1300 733 272 New Zealand power redarcelectronics co nz www redarcelectronics co nz 64 9 222 1024 North America power redarcelectronics com www redarcelectronics com United States 1 704 247 5150 Canada 1 604 260 5512 Mexico 52 558 526 2898 UK Europe power redarcelectronics eu www redarcelectronics eu 44 0 20 393...

Reviews: