background image

2

2

REDARC SOLAR CABLES AND VALUE PACK

REDARC Solar Cables are suitable for use with REDARC Solar products. REDARC Solar products include Solar 

Panels, Solar Blankets, Solar Regulators and REDARC BCDC / BMS Battery chargers. The cables feature 

UV stabilised PVC insulation for outdoor applications, and use genuine Anderson

 to Anderson

 SB

 50 

connectors with silver plated terminals.
The REDARC Solar Value Pack (SRPA20-VP) includes a 5 m Anderson

 to Anderson

 cable (SRC0018), a 

1.5 m Anderson

 to Battery Clip cable (SRC0009) and a 20 A Solar Regulator (SRPA0240). All products in the 

REDARC Solar Value Pack (SRPA-VP) use Anderson

 SB

 50 connectors with silver plated terminals. 

WARNING AND SAFETY INSTRUCTIONS 

SAVE THESE INSTRUCTIONS - THIS MANUAL CONTAINS 

IMPORTANT SAFETY INSTRUCTIONS FOR REDARC 

SOLAR CABLES.

Do not operate Solar products unless you have read and 

understood their associated manuals, and the system is 

set up as per their instructions. REDARC recommends 

that any Solar product is installed by a suitably qualified 

person.

WARNING

RISK OF EXPLOSIVE GASES

:  

Working in the vicinity of lead-acid batteries is 

dangerous. Batteries generate explosive gases during 

normal operation. For this reason, it is of utmost 

importance that you follow the instructions when 

installing and using Solar products.

RISK OF EXPLOSIVE GASES

:  

Batteries should be mounted in a well ventilated area, as 

far as possible from any ignition sources. NEVER smoke 

or allow a spark or flame in the vicinity of a battery or 

engine. This may cause the battery to explode.

RISK OF OVERCHARGING: 

Check the manufacturer’s data for your battery and 

ensure that the voltage of the profile you select does 

not exceed the manufacturer’s recommended maximum 

charging voltage. If the maximum voltage for your 

battery type is too high, please select another charging 

profile.

RISK OF DAMAGE AND INJURY FROM 

IMPROPERLY SECURED PANELS:

 

Solar panels mounted to all types of vehicles, including 

but not limited to, 4x4 Vehicles, RVs, Caravans, are 

subject to high wind and vibration forces when driving. 

Solar panels must be securely attached to the vehicle in 

accordance with all local and national safety standards. 

In addition, the solar mount manufacturer's instructions 

must be adhered to or may be required to be exceeded 

to comply with local and national standards.

CAUTION

1. 

Solar products should not be used by persons 

(including children) with reduced physical, sensory 

or mental capabilities, or lack of experience and 

knowledge, unless they are supervised or have been 

instructed on how to use the appliance by a person 

responsible for their safety. Children should be 

supervised to ensure that they do not play with the 

Solar product. 

2. 

Do NOT use Solar products to charge non–

rechargeable batteries. Doing so may result in harm to 

the user and/or damage to the Solar products.

3. 

Do NOT exceed the current and voltage rating of the 

cables and connectors. Exceeding the recommended 

ratings will cause damage to the components.

4. 

Incorrect connections can subject the Solar products 

to high voltages or currents that will cause damage. 

Ensure the recommended connections and sequences 

are followed.

5. 

Only use Solar products for charging Lead Acid, 

Gel,Calcium content, AGM or Lithium Iron Phosphate 

batteries using a Solar Regulator/Charger suitable for 

the Battery’s chemistry and nominal voltage.

6. 

Solar products are not intended to supply power to a 

low voltage electrical system other than to charge a 

battery. 

7. 

An unconnected Solar panel exposed to light may 

generate voltages up to their rated open-circuit 

voltage on their leads. Completely cover all Solar 

panels with an opaque material during installation, 

and when connecting or disconnecting conductors to 

reduce the chance of an electrical spark.

8. 

Do not use mirrors or other devices to artificially 

concentrate sunlight on Solar panels.

9. 

Solar panels used in series, parallel, or series-parallel 

shall be positioned to receive identical amounts of 

light to reduce risk of damage.

INST142-1

Summary of Contents for SRC0001

Page 1: ...Cables Value Pack SRC0001 SRC0002 SRC0003 SRC0006 SRC0008 SRC0009 SRC0010 SRC0011 SRC0012 SRC0016 SRC0017 SRC0018 SRC0019 SRPA20 VP SRC0001 CK ...

Page 2: ...ounted to all types of vehicles including but not limited to 4x4 Vehicles RVs Caravans are subject to high wind and vibration forces when driving Solar panels must be securely attached to the vehicle in accordance with all local and national safety standards In addition the solar mount manufacturer s instructions must be adhered to or may be required to be exceeded to comply with local and nationa...

Page 3: ...old water for at least 10 minutes and seek medical assistance immediately CONTENTS REDARC SOLAR CABLES AND VALUE PACK 2 WARNING AND SAFETY INSTRUCTIONS 2 1 SRC0001 5m 16 4ft MC4 TO BARE WIRE CONNECTOR 4 2 SRC0002 10m 32 8ft MC4 TO BARE WIRE CONNECTOR 5 3 SRC0003 1 5m 4 9ft MC4 TO BARE WIRE CONNECTOR 6 4 SRC0006 300mm 11 8 MC4 Y CONNECTORS 7 5 SRC0008 1 5m 5ft ANDERSON TO ANDERSON CABLE 8 6 SRC0009...

Page 4: ...mm 16 4 ft 3 9 Part Number SRC0001 Connector MC4 bare wire Conductor Tinned Cooper Current Rating 1 30 A Conductor size AWG 11 Ø2 3 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Sheath black Fuse Type N A Fuse Rating N A 1 Current rating applies when cable is fully extended Use of cable in coiled state is not recommended ...

Page 5: ... mm 32 8 ft 3 9 Part Number SRC0002 Connector MC4 bare wire Conductor Tinned Cooper Current Rating 1 30 A Conductor size AWG 11 Ø2 3 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Sheath black Fuse Type N A Fuse Rating N A 1 Current rating applies when cable is fully extended Use of cable in coiled state is not recommended ...

Page 6: ...00 mm 4 9 ft 3 9 Part Number SRC0003 Connector MC4 bare wire Conductor Tinned Cooper Current Rating 1 30 A Conductor size AWG 11 Ø2 3 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Sheath black Fuse Type N A Fuse Rating N A 1 Current rating applies when cable is fully extended Use of cable in coiled state is not recommended ...

Page 7: ...mm 4 100 mm 4 Specifications for MC4 Y Connectors Length 300 mm 30 mm 11 8 1 2 Part Number SRC0006 Connectors MC4 Y Conductor Tinned Cooper Current Rating 1 30 A Conductor size AWG 11 Ø2 3 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Sheath black Fuse Type N A Fuse Rating N A ...

Page 8: ...0008 Connector Anderson SB 50 Conductor Bare Copper Current Rating 1 50 A Conductor size AWG 11 Ø2 3 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Positive lead red Negative lead black Sheath black Fuse Type N A Fuse Rating N A 1 Current rating applies when cable is fully extended Use of cable in coiled state is not recommended ...

Page 9: ...ber SRC0009 Connector Anderson SB 50 battery clip Conductor Bare Copper Current Rating 1 30 A Conductor size AWG 11 Ø2 3 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Positive lead red Negative lead black Sheath black Fuse Type MIDI Fuse Rating 40 A 1 Current rating applies when cable is fully extended Use of cable in coiled state is not recommended ...

Page 10: ...Part Number SRC0010 Connector Anderson SB 50 battery terminal Conductor Bare Copper Current Rating 1 30 A Conductor size AWG 6 Ø4 1 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Positive lead red Negative lead black Sheath black Fuse Type MIDI Fuse Rating 40 A 1 Current rating applies when cable is fully extended Use of cable in coiled state is not recommended ...

Page 11: ...nderson to Anderson Connector Length 300 mm 10 mm 1 ft 0 4 Part Number SRC0011 Connector Anderson SB 50 Conductor Bare Copper Current Rating 40 A Conductor size AWG 11 Ø2 3 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Positive lead red Negative lead black Sheath black Fuse Type N A Fuse Rating N A ...

Page 12: ... to Anderson Connector Length 300 mm 10 mm 1 ft 0 4 Part Number SRC0012 Connector Anderson SB 50 Conductor Bare Copper Current Rating 40 A Conductor size AWG 11 Ø2 3 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Positive lead red Negative lead black Sheath black Fuse Type N A Fuse Rating N A ...

Page 13: ... Number SRC0016 Connector Anderson SB 50 bare wire Conductor Bare Copper Current Rating 1 40 A Conductor size AWG 10 Ø2 6 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Positive lead red Negative lead black Sheath black Fuse Type N A Fuse Rating N A 1 Current rating applies when cable is fully extended Use of cable in coiled state is not recommended ...

Page 14: ...2 Part Number SRC0017 Connector Anderson SB 50 MC4 Conductor Bare Copper Current Rating 1 30 A Conductor size AWG 10 Ø2 6 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Sheath black Fuse Type N A Fuse Rating N A 1 Current rating applies when cable is fully extended Use of cable in coiled state is not recommended ...

Page 15: ...mber SRC0018 Connector Anderson SB 50 Conductor Bare Copper Current Rating 1 40 A Conductor size AWG 10 Ø2 6 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Positive red Negative black Sheath black Fuse Type N A Fuse Rating N A 1 Current rating applies when cable is fully extended Use of cable in coiled state is not recommended ...

Page 16: ...1 2 Connector Anderson SB 50 Conductor Bare Copper Current Rating 1 30 A Conductor size AWG 10 Ø2 6 mm Voltage Rating 50 VDC max Insulation Sheath UV Stabilised PVC Colour Coding Positive red Negative black Sheath black Fuse Type N A Fuse Rating N A 1 Current rating applies when cable is fully extended Use of cable in coiled state is not recommended ...

Page 17: ...le plug and play set up of the system The included cables allow the panels to be positioned up to 5 m from the regulator Value Pack Contents 1 SRPA0240 20 A Solar Regulator 2 SRC0018 5 m Anderson to Anderson cable 3 SRC0009 1 5 m Anderson to battery clip cable 2 1 3 15 SRC0001 CK MC4 CONNECTOR KIT The SRC001 CK includes a male and female MC4 connector ...

Page 18: ... the Solar Panels is connected directly to the regulator Refer to the manufacturer s instructions The SRC0009 Battery clip cable is intended for a portable short term connection and is not to be left connected permanently 16 2 Fuse Protection Fuse protection is required for wire and component protection in case of short circuit Fuses must be fitted as close as possible to the battery positive term...

Page 19: ...edarc com au warranty REDARC Electronics Pty Ltd 23 Brodie Road North Lonsdale SA 5160 Australia North America www redarcelectronics com warranty REDARC Corporation c o Shallco Inc 308 Component Dr Smithfield NC 27577 USA Australia 1300 REDARC 1300 733 272 New Zealand 64 9 222 1024 UK and Europe 44 0 20 3930 8109 USA 1 704 247 5150 Canada 1 604 260 5512 Mexico 52 558 526 2898 ...

Page 20: ...il Australia and other Global regions power redarc com au www redarc com au 1300 REDARC 1300 733 272 New Zealand power redarcelectronics co nz www redarcelectronics co nz 64 9 222 1024 North America power redarcelectronics com www redarcelectronics com United States 1 704 247 5150 Canada 1 604 260 5512 Mexico 52 558 526 2898 UK Europe power redarcelectronics eu www redarcelectronics eu 44 0 20 393...

Reviews: