20
3
INSTALLATION
3.1
Mounting
Install the inverter in a well-ventilated area with reasonable clearance, avoid installing the inverter in
a zero-clearance compartment or obstruct the ventilation openings, doing so may result in the inverter
overheating and ultimately damage the inverter.
The power inverter should be used in an environment that meets the following requirements:
1.
Dry — Do not allow water to drip on or enter into the inverter. Do not allow moisture to
condense on the inverter.
2.
Cool — Ambient air temperature should be between 32°F (0°C) and 104°F (40°C).
3.
Safe — Do not install the inverter in a battery compartment or other areas where volatile fumes
may exist, such as fuel storage areas or engine compartments.
4.
Ventilated — Keep the inverter at a distance (at least 1" (25 mm) away from surrounding objects.
Ensure the vents on the rear and the bottom of the unit are not obstructed.
5.
Dust — Do not install the inverter in a dusty environment where the dust can enter into the unit both
when the fan is operating and not operating.
6.
Fused – A fuse must be fitted between the battery and the inverter, positioned as close to the
battery as possible.
7.
Do not mount the inverter where it will be exposed to the gasses produced by the battery.
These gasses present a risk of explosion and are very corrosive, prolonged exposure may
damage the inverter.
WARNING
RISK OF ELECTRICAL SHOCK. DO NOT EXPOSE THE INVERTER TO RAIN, SNOW, SPRAY, BILGE OR DUST. DOING SO
MAY RESULT IN DAMAGE TO THE INVERTER OR OTHER APPLIANCES INSTALLED IN THE SYSTEM OR RESULT IN
ELECTRIC SHOCK OR FIRE.
RISK OF ELECTRICAL SHOCK. DO NOT DISASSEMBLE THE INVERTER - THE INTERNAL CIRCUITRY CONTAINS
HAZARDOUS VOLTAGES. ATTEMPTING TO SERVICE THE UNIT YOURSELF MAY RESULT IN ELECTRIC SHOCK OR FIRE
AND WILL VOID THE UNIT WARRANTY.
TABLE 3.1.4.1: Recommended Mounting
Horizontal Wall Mount, Base
Down
Horizontal Mount, Base
down / up
Do not mount in a vertical
configuration
3.2
Ventilation Fan
The fan is load and temperature controlled and will operate when the AC Power Consumption and
temperature requires it. The fan will also occasionally come on when no load is connected. Ensure that
the fan is not obstructed and the inverter is at a distance of at least 1" (25 mm) from surrounding objects.