PT500-2
Service Manual
Chapter 7
ADJUSTMENT
7.1 Required Test Equipment
Table 7.1
Number
Name
Parameter requirements
1
Computer
Above P2, compatible IBM PC, WINDOWS
98/ME/2000/XPOperating System
2
Programming
software
PT500 Programming software
3
Programming
cable
Special Serial/USB (CPL-01) programming cable
5
DC regulator
Output voltage:7.5V, output electric current:≥ 5A
6
RF power meter
Test range: 0.5---10W
Frequency range: 100MHz
—500MHz
Resistance: 50Ω SWR
≤
1.2
7
Frequency
meter
Frequency range: 0.1
—600MHz
Frequency accuracy: higher than±1×10
-6
Sensitivity: higher than 100mV
8
Frequency
deviator
Frequency range: DC
—600MHz
Test range: 0--±5kHz
9
DMM
Input resistance: above 10MΩ/V DC, capable of
measuring voltage, electric current and resistance.
10
Audio signal
generator
Frequency range:2---3000Hz Output
level: 1---500mV
11
RF power
attenuator
Decrement: 40db or 50db
Receive power : higher than10W
12
Standard signal
source
Frequency range:10MHz---1000MHz Output
level:0.1uV~32mV (-127dBm~-17dBm)
13
Oscilloscope
Frequency range: DC~20MHz
Test range: 10mV~20V
Summary of Contents for PT500-2