64
O
64
15-CLEANING AND MAINTENANCE
CLEANING THE TROLLEY
Red recommends checking the level of the ash inside the trolley every 15 days with the boiler switched off and in any case empty the
container every two months(*).
Carry out this check as follows:
• turn off the boiler
• disconnect the trolley from the boiler with the two side levers
• close cap “O” near the feed screw insertion hole (to avoid loosing ash during transport)
• open the trolley cover with the two levers
• check the level of the pellets
If the level of ash is more than 50%, empty the container.
Two more steps are required before replacing the trolley:
• check the ash pan and empty it, if necessary (see explanation on the following pages)
• check the cleanliness of the brazier (see explanation on the previous page)
In any case, check the level of the ash deposited in the trolley every 15 days.
*The frequency with which the trolley, lower ash pan and
brazier must be cleaned depends on the type of pellet used. See
the instructions on the previous page.