14
Calibration
There exist three calibrations in MAGIC-2.
1. Probe Calibration
2. Laser Pointer Calibration
3. Vise Center Calibration
You can enter each setting modes by pressing a certain key when the power is switched on.
Entering Calibration Mode
When turn power switch on, press
or
key for certain period of time.
Probe Calibration:
1.
Hold a tool at its shortest.
(***Dragging tool is recommended)
2. Turn power ON pressing
, then wait for 2 seconds with the button pressed until beep,
“beep- beep-”, is heard. Tool will be moved onto center of vise with Z axis lowered.
3. Place a flat material on the vise and fasten. Loose tool fastening bolt and make tool touch
the material surface then fasten the bolt again.
(**Pressing the below buttons will help easy calibration on making tool touch the material.)
Short pressing:
Moves tool(Z axis) UP
As long as it is pressed:
Moves tool(Z axis) DOWN
4.
Press
button for 2 seconds to complete the calibration. Tool will touch the material and
calibration is completed.
Key
Pressing Time
Calibration
Short Press
Laser Pointer Calibration
Long Press(for more than 2
seconds)
Probe Calibration
Short Press
Vise Center Calibration.
POWER Key