background image

Wired Router Hardware & Installation Guide

4

Statement of Limited Warranty

Red

 

Lion,

 

manufacturer

 

of

 

Red

 

Lion

 

products,

 

warrants

 

to

 

Buyer

 

that

 

products,

 

except

 

software,

 

manufactured

 

by

 

Red

 

Lion

 

will

 

be

 

free

 

from

 

defects

 

in

 

material

 

and

 

workmanship.

 

Red

 

Lion’s

 

obligation

 

under

 

this

 

warranty

 

will

 

be

 

limited

 

to

 

repair

ing

 

or

 

replacing,

 

at

 

Red

 

Lion’s

 

option,

 

the

 

defective

 

parts

 

within

 

three

 

(3)

 

years

 

of

 

the

 

data

 

of

 

installation,

 

or

 

within

 

three

 

(3)

 

years

 

of

 

the

 

date

 

of

 

shipment

 

from

 

the

 

point

 

of

 

manufacture,

 

whichever

 

is

 

sooner.

 

Products

 

may

 

be

 

returned

 

by

 

Buyer

 

only

 

after

 

permission

 

has

 

been

 

obtained

 

from

 

Red

 

Lion.

 

Buyer

 

will

 

prepay

 

all

 

freight

 

charges

 

to

 

return

 

any

 

products

 

to

 

the

 

repair

 

facility

 

designated

 

by

 

Red

 

Lion.

This

 

limited

 

warranty

 

does

 

not

 

cover

 

losses

 

or

 

damages

 

which

 

occur

 

in

 

shipment

 

to

 

or

 

from

 

Buyer

 

or

 

due

 

to

 

improper

 

installation,

 

maintenance,

 

misuse,

 

neglect

 

of

 

any

 

cause

 

other

 

than

 

ordinary

 

commercial

 

or

 

industrial

 

applications.

 

In

 

par

ticular,

 

Red

 

Lion

 

makes

 

no

 

warranties

 

whatsoever

 

with

 

respect

 

to

 

implied

 

warranties

 

or

 

merchantability

 

or

 

fitness

 

for

 

any

 

particular

 

purpose.

 

All

 

such

 

warranties

 

are

 

hereby

 

expressly

 

disclaimed.

 

No

 

oral

 

or

 

written

 

information

 

or

 

advice

 

given

 

by

 

Red

 

Lion

 

or

 

Red

 

Lion’s

 

representative

 

shall

 

create

 

a

 

warranty

 

or

 

in

 

any

 

way

 

increase

 

the

 

scope

 

of

 

this

 

warranty.

This

 

limited

 

warranty

 

is

 

in

 

lieu

 

of

 

all

 

other

 

warranties

 

whether

 

oral

 

or

 

written,

 

expressed

 

or

 

implied.

 

Red

 

Lion’s

 

liability

 

shall

 

not

 

exceed

 

the

 

price

 

of

 

the

 

individual

 

units,

 

which

 

are

 

the

 

basis

 

of

 

the

 

claim.

 

In

 

no

 

event

 

shall

 

Red

 

Lion

 

be

 

liable

 

for

 

any

 

loss

 

of

 

profits,

 

loss

 

of

 

use

 

of

 

facilities

 

or

 

equipment,

 

or

 

other

 

indirect,

 

incidental

 

or

 

consequential

 

damages.

Safety Information

Environmental:

Pollution

 

degree:

 

2

 

(Per

 

IEC

 

61010

1)

Electrical:

Properly

 

ground

 

the

 

unit

 

before

 

connecting

 

anything

 

else

 

to

 

it.

 

If

 

the

 

equipment

 

is

 

used

 

in

 

a

 

manner

 

“not”

 

specified

 

by

 

Red

 

Lion,

 

the

 

protection

 

provided

 

by

 

the

 

equipment

 

may

 

be

 

impaired.

Overvoltage

 

category:

 

II

 

(Per

 

IEC

 

61010

1)

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Summary of Contents for RAM-6021

Page 1: ...RAM 6021 Wired Router Hardware and Installation Guide April 2014 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 2: ...tion Guide CHANGE HISTORY Version Date Description r01 April 2014 Modifications to power specifications Included installa tion and hazardous area warnings Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 3: ...LED 9 1 1 6 Data Interface Specifications Serial Ethernet USB 9 1 1 7 RESET Button Functions 10 Chapter 2 Hardware Installation 11 2 1 Mounting the RAM 6021 Wired Router 11 2 2 DIN Rail Mounting Removal 11 2 3 Ethernet Cable 12 2 4 USB Cable 12 2 5 Serial Cable 12 2 6 Power Source 13 Chapter 3 Service and Support Information 14 3 1 Service Information 14 3 2 Product Support 14 Phone 800 894 0412 F...

Page 4: ...zardous AVERTISSEMENTS POUR INSTALLATION ET ENDROITS DANGEREUX Instructions d installation et d utilisation sont fournies avec chaque unité Les instructions d installation peuvent être fournies sur papier ou CD Les instructions d installations doivent contenir une déclaration selon laquelle tous courants câblage d entrée et de sortie I O doit être conforme à la classe I Division 2 méthodes de câbl...

Page 5: ...trial applications In par ticular Red Lion makes no warranties whatsoever with respect to implied warranties or merchantability or fitness for any particular purpose All such warranties are hereby expressly disclaimed No oral or written information or advice given by Red Lion or Red Lion s representative shall create a warranty or in any way increase the scope of this warranty This limited warrant...

Page 6: ...l Interface 1x RS 232 Serial DB9 115200bps USB Interface 1x USB 2 0 mini configuration port LED Indicators Power W RS232 Ethernet Link Activity Mechanical Dimensions Steel 120 x 96 x 51 mm 4 7 x 3 77 x 2 0 Weight 544g 1 2 lbs Redundant Power Input 4 pin screw terminal Side mounted 2 5 mm barrel connector 8 30 VDC 12 or 24 VDC nominal Input current max 150 mA Power consumption 4 5W typical max with...

Page 7: ...CC part 15 and Industry Canada ICES 003 CE RoHS Inputs Output 1x digital output 1x digital analog input one active Warranty 3 years on design and manufacturing defects WEEE compliance These devices comply with the WEEE directive Do not throw away these devices in the standard trash Contact Red Lion regarding proper disposal RoHS compliance These devices comply with the RoHS directive and are consi...

Page 8: ...2 5mm Barrel Connector Power is supplied to the router via the barrel connector on the left side of the RAM 6021 router The contacts are described as follows Warning DC 2 5mm barrel connector shall not be used in hazardous locations Power connector facing front Pin Name Description 1 GND Ground 2 PWR Power supply input 8 to 30 VDC 3 OUT Digital output 4 IN Digital and analog input Power connector ...

Page 9: ...imum VDC 30VDC open circuit Absolute Minimum VDC 0 4VDC open circuit 1x Digital Input DIN Configuration un isolated level detection reference to ground Active level 1 6VDC to 30VDC Inactive level 0VDC to 1 3VDC Absolute Minimum VDC 0 3VDC Absolute Maximum VDC 33VDC Leakage IDC at 5VDC 150uADC 1x Analog Input Shared with Digital Input DIN AI1 Configuration un isolated input reference to ground Reso...

Page 10: ...are version 4 17 and later standard Windows RNDIS drivers are used and no additional driver is required from Red Lion website The unit is compatible with Windows 7 8and other operating systems OSX Linux etc 1 1 6 3 Serial Port The router s serial port is an RS232 DCE compliant with EIA 232 standard The connector used is DB9 female and is shown in the illustration below Figure 1 Serial connector lo...

Page 11: ...quickly To restore default settings for older versions rerun the SN Reflashing procedure found on our website FW Upgrade Press and hold between 10 and 15 seconds W LED flashes quickly Puts the router in advanced firmware upgrade mode by restarting the router and running the boot loader only Do not use this mode unless instructed to by Red Lion Technical Support Phone 800 894 0412 Fax 888 723 4773 ...

Page 12: ...Removal The RAM 6021 has a DIN rail clip pre mounted to the back of the unit To panel mount the unit the clip can be removed easily by removing the three 3 screws holding it in place See the image at right for reference The DIN clip has an integral spring mechanism that keeps it securely attached to the rail Refer to the diagrams below for how to mount and remove the unit to a standard EN50022 DIN...

Page 13: ...r via the USB port you will need a Type A plug to Type B plug USB cable for the mini Type B plug to Type A plug for the RAM 6021 wired router In order for the USB connection to work you need to install the Sixnet USB driver which is available at Red Lion website Note With firmware version 4 17 and later standard Windows RNDIS drivers are used and no additional driver is required from Red Lion webs...

Page 14: ...The wiring will vary depending on whether the attached serial device is a DTE or DCE 2 6 Power Source As described in the Power specifications and consumption section the router can be powered using 4 pin screw terminal Side mounted 2 5mm barrel connector IMPORTANT Any installation involving electrical wiring and connections should be done by someone who is experienced in this field WARNING DC 2 5...

Page 15: ...ur warranty You will not be billed if the repair is covered under warranty Please supply us with as many details about the problem as you can The information you supply will be written on the RO form and supplied to the repair department before your unit arrives This helps us to provide you with the best service in the fastest manner Repairs are completed as soon as possible If you need a quicker ...

Reviews: