background image

LIMITED WARRANTY

The Company warrants the products it manufactures against defects in materials and workmanship 
for a period limited to two years from the date of shipment, provided the products have been stored, 
handled, installed, and used under proper conditions. The Company’s liability under this limited 
warranty shall extend only to the repair or replacement of a defective product, at The Company’s 
option. The Company disclaims all liability for any affirmation, promise or representation with 
respect to the products.
The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against 
damages, claims, and expenses arising out of subsequent sales of RLC products or products 
containing components manufactured by RLC and based upon personal injuries, deaths, property 
damage, lost profits, and other matters which Buyer, its employees, or sub-contractors are or may be 
to any extent liable, including without limitation penalties imposed by the Consumer Product Safety 
Act (P.L. 92-573) and liability imposed upon any person pursuant to the Magnuson-Moss Warranty 
Act (P.L. 93-637), as now in effect or as amended hereafter.
No warranties expressed or implied are created with respect to The Company’s products except those 
expressly contained herein. The Customer acknowledges the disclaimers and limitations contained 
herein and relies on no other warranties or affirmations.

Red Lion Controls
Headquarters
20 Willow Springs Circle
York PA 17406
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839

Red Lion Controls

China

Unit 101, XinAn Plaza

Building 13, No.99 Tianzhou Road

ShangHai, P.R. China 200223

Tel +86 21 6113-3688

Fax +86 21 6113-3683

Red Lion Controls

Europe

Printerweg 10

NL - 3821 AD Amersfoort

Tel +31 (0) 334 723 225

Fax +31 (0) 334 893 793

Red Lion Controls

India

54, Vishvas Tenement

GST Road, New Ranip,

Ahmedabad-382480 Gujarat, India

Tel +91 987 954 0503

Fax +91 79 275 31 350

Summary of Contents for PAXLI

Page 1: ...vironmental conditions A DIP switch is used to control the backlight for the units label The meters have a NEMA 4X IP65 sealed bezel and extensive testing of noise effects to CE requirements allowing the meter to provide a tough yet reliable application solution SAFETY SUMMARY All safety related regulations local codes and instructions that appear in the literature or on equipment must be observed...

Page 2: ... the Meter 6 Troubleshooting 7 Calibration 7 TABLE OF CONTENTS ORDERING INFORMATION PAXL 0 I Current Input V Voltage Input 0 A AC Input D DC Input Meter Part Numbers Accessories Part Numbers APSCM100 APSCM010 PAXLBK30 100 Amp DC Current Shunt 10 Amp DC Current Shunt Units Label Kit Accessory APSCM PAXLBK Accessories TYPE PART NUMBERS DESCRIPTION MODEL NO ...

Page 3: ...ARTH 350 volt peak 16 CERTIFICATIONS AND COMPLIANCES SAFETY UL Recognized Component File E179259 UL61010A 1 CSA C22 2 No 61010 1 Recognized to U S and Canadian requirements under the Component Recognition Program of Underwriters Laboratories Inc UL Listed File E137808 UL508 CSA C22 2 No 14 M95 LISTED by Und Lab Inc to U S and Canadian safety standards Type 4X Enclosure rating Face only UL50 IECEE ...

Page 4: ...230 115 REAR TERMINALS FRONT DISPLAY 4 2 0 SETTING THE JUMPERS AND SWITCHES SWITCH FUNCTION 1 Decimal Point 1 000 0 2 Decimal Point 2 00 00 3 Decimal Point 3 0 000 4 Backlight Annunciator for Units Label 5 Enables the Scaling Pot 1 0 INSTALLING THE METER Installation The PAX meets NEMA 4X IP65 requirements when properly installed The unit is intended to be mounted into an enclosed panel Prepare th...

Page 5: ... enclosure which is properly connected to protective earth 2 Never run Signal or Control cables in the same conduit or raceway with AC power lines conductors feeding motors solenoids SCR controls and heaters etc The cables should be run in metal conduit that is properly grounded This is especially useful in applications where cable runs are long and portable two way radios are used in close proxim...

Page 6: ...y zero voltage can display a value of zero DIVISION FACTOR FORMULA VT x D D P D F D R WHERE VT Maximum Transducer Output D D P Display Decimal Point D F Division Factor D R Desired Reading D D P 0 000 1 The Display Decimal Point 00 00 10 D D P is determined by 000 0 100 the desired decimal point 0000 1000 placement in the readout After the Division Factor for the application has been calculated th...

Page 7: ...Scaling to obtain a numerical readout higher than the normal value of the current can also be accomplished in most cases by selecting a lower current range However the maximum current for the range must not be exceeded See Specifications for maximum input currents PROCESS CIRCUITRY VDC S3 S2 S1 S4 COMMON SIGNAL 0 199 9mA 0 19 99mA 1 Ω 9 Ω S5 0 1 999mA 0 199 9µA 90 Ω 900 Ω POT SCALE 1 Ω 0 1 999A 1 ...

Page 8: ...uyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer Product Safety Act P L 92 573 and liability imposed upon any person pursuant to the Magnuson Moss Warranty Act P L 93 637 as now in effect or as amended hereafter No warranties expressed or implied are created with respect to The Company s products except those ex...

Reviews: