background image

 
ET-18MG-MIL_manual.r04.doc 

Page 2 of 12   

              Last Revised: 17-Dec-13 

RED LION Protected Technology Policy - 

Red Lion protects your investment in Red Lion systems with 

long-term planned technology and our unique Protected Technology Policy. We will continue to support the specified 
capabilities of standard Red Lion products for at least five years (twenty years for Industrial Managed Switches). We 
plan each product improvement and new feature to be upward compatible with existing designs and installations. Our 
goals are to make each new software release bring new power to your Red Lion systems and have every existing 
feature, applications program and data file continue to work. We protect your investment even further with a liberal 
five-year trade-in policy. Exchange standard products for upgraded versions of the same product to take advantage of 
new features and performance improvements at any time for five years. A prorated trade-in allowance will be given 
for your existing equipment. Red Lion protects your long-term productivity with state-of-the-art planned technology 
and continued support.

 

 
Red Lion Statement of Limited Warranty - 

Red Lion, manufacturer of Red Lion products, warrants to 

Buyer that products, except software, manufactured by Red Lion will be free from defects in material and 
workmanship. Red Lion's obligation under this warranty will be limited to repairing or replacing, at Red Lion's option, 
the defective parts within one year of the date of installation, or within 18 months of the date of shipment from the 
point of manufacture, whichever is sooner. Products may be returned by Buyer only after permission has been 
obtained from Red Lion. Buyer will prepay all freight charges to return any products to the repair facility designated 
by Red Lion. This limited warranty does not cover losses or damages which occur in shipment to or from Buyer or 
due to improper installation, maintenance, misuse, neglect or any cause other than ordinary commercial or industrial 
applications. In particular, Red Lion makes no warranties whatsoever with respect to implied warranties of 
merchantability or fitness for any particular purpose. All such warranties are hereby expressly disclaimed. No oral or 
written information or advice given by Red Lion or Red Lion’s representative shall create a warranty or in any way 
increase the scope of this warranty. This limited warranty is in lieu of all other warranties whether oral or written, 
expressed or implied. Red Lion's liability shall not exceed the price of the individual units, which are the basis of the 
claim. In no event shall Red Lion be liable for any loss of profits, loss of use of facilities or equipment, or other 
indirect, incidental or consequential damages. 

 

INSTALLATION AND HAZARDOUS AREA WARNINGS - 

These products should not be used to 

replace proper safety interlocking. No software-based device (or any other solid-state device) should ever be 
designed to be responsible for the maintenance of consequential equipment or personnel safety. In particular, 
Red Lion disclaims any responsibility for damages, either direct or consequential, that result from the use of 
this equipment in any application. All power, input and output (I/O) wiring must be in accordance with Class 
I, Division 2 wiring methods and in accordance with the authority having jurisdiction. See section 1 for other 
important installation warnings.

 

 

FCC Statement - 

This equipment has been tested and found to comply with the limits for a Class B digital device, 

pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 
interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if 
not installed and used in accordance with the instructions, may cause harmful interference to radio communications. 
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause 
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, 
the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate 
the receiving antenna; Increase the separation between the equipment and receiver; Connect the equipment into an 
outlet on a circuit different from that to which the receiver is connected; Consult the dealer or an experienced 
radio/TV technician for help.

 

 
Copyright & Trademarks - 

Copyright 

2013 Sixnet, Inc. All Rights Reserved. 

 

 

 

Note:

 All information in this document is subject to change without notice. 

Summary of Contents for ET-18MG-MIL-SS

Page 1: ...ion and Wiring Manual Contents at a Glance Section 1 General Information Page 3 Section 3 Mechanical and Installation Page 5 Section 4 Power and Communications Page 7 Section 5 Mating Connections Page 12 This manual applies to the following products ET 18MG MIL SS Switch with 16 10 100 ports and 2 Gigabit fiber optic ports ...

Page 2: ...aimed No oral or written information or advice given by Red Lion or Red Lion s representative shall create a warranty or in any way increase the scope of this warranty This limited warranty is in lieu of all other warranties whether oral or written expressed or implied Red Lion s liability shall not exceed the price of the individual units which are the basis of the claim In no event shall Red Lio...

Page 3: ...18 Ethernet ports Ethernet switch type Managed unmanaged optional Ethernet protocols supported All IEEE 802 3 10 100 Ethernet ports 1 16 receptacle MIL DTL 38999 Series III w 22D socket contacts insert style 35 Ethernet speed 10 100BaseTX Auto negotiation 10 or 100 Mbps Ethernet MDI MDIX TD RD Auto crossover and auto polarity Ethernet isolation 1500 VRMS 1 minute Gigabit Ethernet ports 17 18 recep...

Page 4: ...OT WORK ON EQUIPMENT DURING PERIODS OF LIGHTNING ACTIVITY WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS 1 DIVISION 2 ZONE 2 WARNING EXPLOSION HAZARD WHEN IN HAZARDOUS LOCATIONS DISCONNECT POWER BEFORE REPLACING OR WIRING UNITS WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS Consig...

Page 5: ... installing the switch The mounting ears are included and pre attached to the switch They may be removed and reversed as desired 1 75 44 4 SIXNET Military Ethernet Rack Switch Shown with cap installed tether not shown Make sure to allow enough room for the desired plug backshell and wiring 1 2 3 4 5 6 7 Console LED Gigabit GND Power 8 9 10 11 12 13 14 Ø0 25 Ø6 4 15 16 17 32 439 9 14 17 359 9 16 67...

Page 6: ...ET 18MG MIL_manual r04 doc Page 6 of 12 Last Revised 17 Dec 13 Front View of Switch Back View of Switch Side and Top View of Switch ...

Page 7: ...rrosion resistance All mating connectors will self lock with one 360 degree turn of the coupling nut Typical MIL STD 38999 Connectors shown with tethered plugs Typical MIL STD 38999 Plug not typically supplied with switch Grounding Use the provided ground stud and nut to connect the switch to a suitable safety chassis or earth ground Use of heavy gauge at least 16 AWG grounding wire is recommended...

Page 8: ...e the power connections as shown in the diagram below Power Connector Location Power Connector Pinout Pin male Contacts Shell A 9 Insert 35 Contacts P Keying N 2 3 4 5 6 1 DC Supply 1 3 no connection on pins 2 4 5 and 6 ET 18MG MIL Power Input Receptacle Recommended Plug w cadmium plating socket contacts Normal keying Amphenol D38999 26WA35SN ...

Page 9: ...ction refer to the software user manual on how to access the switch via this console port Console Connector Location Console Connector Pinout 3 RS232 TD Console Port Receptacle output Shell A 9 Insert 35 Contacts S Keying N 1 GND 2 RS232 RD input 1 2 3 4 5 6 no connection on pins 4 5 and 6 Socket female Contacts Recommended Plug w cadmium plating pin contacts Normal keying Amphenol D38999 26WA35PN...

Page 10: ...sabled or configured for fixed settings via one of the management interfaces See the software user manual for details Ethernet Connector Location typical Ethernet Connector Pinout ET 18MG MIL Ethernet 10 100 Receptacles RX RX TX TX 1 2 3 4 6 5 Shell A 9 Insert 35 Contacts S Keying N 2 3 6 1 no connection on pins 4 and 5 Socket female Contacts Recommended Plug w cadmium plating pin contacts Normal ...

Page 11: ... ports are fiber optic They are singlemode 1310 nm for connection distances up to 10 km Ethernet Connector Location Ethernet Connector Pinout B A Gigabit Fiber Receptacle A B TXD RXD Socket female Contacts Recommended Plug w cadmium plating pin contacts Normal keying Amphenol Plug CF 529611 2P Amphenol Contact CF 198096 008 125 microns ...

Page 12: ...ly us with as many details about the problem as you can The information you supply will be written on the RMA form and supplied to the repair department before your unit arrives This helps us to provide you with the best service in the fastest manner Normally repairs are completed in two days Sometimes difficult problems take a little longer to solve If you need a quicker turnaround ship the unit ...