background image

7

DESCRIPTION

MODEL NO.

LOW SPEED

CONTACT INPUT

*CUB7P

VOLTAGE

INPUT

HIGH SPEED LOGIC

INPUT

BNL

Replacement 3 V Lithium Battery

Counter; w/Red Backlighting

Counter, w/Yel-Grn Backlighting

Counter; Positive Image Reflective

Counter; w/Red Backlighting

Counter, w/Yel-Grn Backlighting

Counter; Positive Image Reflective

Counter; w/Red Backlighting

Counter, w/Yel-Grn Backlighting

Counter; Positive Image Reflective

PART NUMBER

CUB7P000
CUB7P010
CUB7P020
CUB7P100
CUB7P110
CUB7P120
CUB7P200
CUB7P210
CUB7P220

BNL10000

* Battery is included with unit.

ORDERING INFORMATION

TROUBLESHOOTING

For further technical assistance, contact technical support at the appropriate company numbers listed.

AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]

Summary of Contents for CUB7P0

Page 1: ...r viewing window The sealed front panel with the silicone rubber buttons meets NEMA 4X IP65 specifications for wash down and or dusty environments when properly installed SAFETY SUMMARY All instructio...

Page 2: ...AL INPUT LS terminal 4 See Count Edge under Programming for incrementing edge of input signal Contact Input CUB7P0xx 30 Hz max from Switch Contact or solid state Transistor Switch to Common witha50 du...

Page 3: ...ble to the unit to suppress power line interference Install them near the power entry point of the enclosure The following EMI suppression devices or equivalent are recommended Ferrite Suppression Cor...

Page 4: ...d to be mounted into an enclosed panel The viewing window and reset button are factory sealed for a washdown environment A sponge rubber gasket and mounting clip are provided for installing the unit i...

Page 5: ...en the LS input and Common Any off state leakage current may prevent the counter from operating properly WARNING If voltage input is connected to circuits above 30 Vrms any lead may be at hazardous li...

Page 6: ...put voltage the neutral of the single phase AC signal is connected to Terminal 1 COM and line hot is connected to Terminal 4 LS The DC supply for the backlighting is connected as shown in the drawing...

Page 7: ...ctive Counter w Red Backlighting Counter w Yel Grn Backlighting Counter Positive Image Reflective PART NUMBER CUB7P000 CUB7P010 CUB7P020 CUB7P100 CUB7P110 CUB7P120 CUB7P200 CUB7P210 CUB7P220 BNL10000...

Page 8: ...armless from defend and indemnify RLC against damages claims and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal...