red lion CR3000 series Manual Download Page 3

 

-3-

Released  2018-09-10

Bulletin No. CR3000- B

Drawing No. LP1042 

INSTALLING

 

AND

 

POWERING

 

THE

  

CR3000

10.4 inch

10.78 (273.73)

11.14 (282.96)

8.87

(225.29)

8.50

(215.99)

7.87

(199.9)

2.00 (50.8)

THIS VIEW SHOWN

WITH MOUNTING PLATE

AND BRACKETS

separately

Module sold

1.26 (32)

CR3000

 

10

MOUNTING

 

INSTRUCTIONS

This operator interface is designed for through-panel

mounting. The 7, 10 and 15 inch HMIs can be VESA
mounted with the addition of a VESA mount adapter plate.
This plate allows mounting to a standard 75 x 75 mm VESA
bracket. The mounting surface should have a minimum
thickness of 0.06" (1.53 mm) and maximum thickness of
0.375" (9.53 mm). Cut the mounting hole per the dimensions
shown in the diagram. Care should be taken to remove any
loose material from the mounting cut-out to prevent that
material from falling into the operator interface during
installation. 

Caution: Only the screws provided with the VESA adapter 
plate should be used to mount the CR3000. Unit cannot be 
VESA mounted if an expansion module will be used.

For hazardous location installation the following shall be

taken into consideration:

-  

This device is open-type and must be mounted in a

suitable dust-tight end-enclosure in accordance with

articles 500 and 502 of the NEC and positioned so only

the face of the display is exposed.

-  Must be wired using Division 2 wiring methods as

specified in article 501-4(b), 502-4(b), and 503-3(b) of
the National Electric Code, NFPA 70 for installation
within the United States, or as specified in section 19-
152 of Canadian Electrical Code for installation in
Canada.

-  Combinations of equipment in your system are subject to

investigation by the local Authority having jurisdiction at
the time of installation.

Ǝ3$1(/&87287

Ǝ3$1(/&87287

Ǝ3$1(/&87287

$//72/(5$1&(6PP

5

5

5

5

5

5

5

5

Ǝ3$1(/&87287

0XVWPHHWKROHWROHUDQFHVSHFLILFDWLRQIRU

IXOO1(0$DQG,3LQJUHVVSURWHFWLRQ

11.42

(290.1)

14.36 (364.6)

11.38

(289.1)

14.31 (363.5)

THIS VIEW SHOWN

WITH MOUNTING PLATE

AND BRACKETS

15.0 inch

2.64 (67.2)

1.26 (32)

Module sold

separately

10.38

(263.7)

CR3000

 

15

Summary of Contents for CR3000 series

Page 1: ...lowing configuration changes to be made and saved to the card for later transfer The CR3000 range of HMIs is programmed with Red Lion s Crimson 3 1 software Crimson offers easy to use drag and drop co...

Page 2: ...E Approved EN 61326 1 Immunity to Industrial Locations Emission CISPR 11 Class A IEC EN 61010 1 RoHS Compliant UL Hazardous File E317425 Type 4X Indoor IP66 Enclosure rating Face only 9 CONNECTIONS Hi...

Page 3: ...should be used to mount the CR3000 Unit cannot be VESA mounted if an expansion module will be used For hazardous location installation the following shall be taken into consideration This device is o...

Page 4: ...th ground to eliminate the buildup of electrostatic charges The chassis ground is not connected to signal common of the unit Maintaining isolation between earth ground and signal common is not require...

Page 5: ...on at the load is always a good design practice to limit EMI Although the use of a snubber or varistor could be used Red Lion part numbers Snubber SNUB0000 Varistor ILS11500 or ILS23000 7 Care should...

Page 6: ...ations RS232 PORTS The CR3000 has two RS232 serial ports Although only one of these ports can be used for programming both ports can be used for communications with a PLC The serial ports can be used...

Page 7: ...t Website www redlion net Inside US 1 877 432 9908 Outside US 1 717 767 6511 BATTERY TIME KEEPING A battery is used to keep time when the unit is without power The battery of a CR3000 unit does not af...

Page 8: ...respect to any such Product during the Warranty Period Company shall in its sole discretion either i repair or replace the Product or ii credit or refund the price of Product provided that if Company...

Reviews: