background image

2

2.85 (72.5)

4.06 (103)

2.95

(75.0)

0.92

(23.3)

(26.0)

1.02

AC 100-120 / 220-240V

N

24-28V

DC on

24V 

+ +

3.9A

Power Supply

L

PSDR095W

NEC Class 2

_

_

 DIMENSIONS  In inches (mm)

Before operating this unit please read this manual thoroughly and retain this 

manual for future reference! This device may only be installed and put into 

operation by qualified personnel. If damage or malfunction should occur 

during operation, immediately turn power off and send unit to the factory for 

inspection. The unit does not contain serviceable parts. The tripping of an 

internal fuse (if included) is caused by an internal defect. The information 

presented in this document is believed to be accurate and reliable and may 

change without notice. 

Intended Use: This device is designed for installation in an enclosure and is 

intended for general use such as in industrial control, office, communication, 

and instrumentation equipment. Do not use this device in equipment, where 

malfunction may cause severe personal injury or threaten human life.

INSTALLATION

Mounting orientation must be output terminals on top and input terminals 

on the bottom. Do not obstruct air flow as the unit is convection cooled. 

Ventilation grid must be kept free of any obstructions. Maintain specified 

installation clearances when power supplies are permanently fully loaded:

TERMINALS AND WIRING

Use the appropriate copper cables as listed in the specifications and follow 

national installation codes and regulations! Ensure that all strands of a 

stranded wire enter the terminal connection! Ferrules are allowed. Unused 

terminal must be closed.

WARNING

Risk of electrical shock, fire, personal injury or death.

 

«

Do not use the power supply without proper grounding (Protective Earth).

 

«

Turn power off before working on the device. Protect against inadvertent 

re-powering.

 

«

Make sure that the wiring is correct by following all local and national 

codes.

 

«

Do not modify or repair the unit.

 

«

Do not open the unit as high voltages are present inside.

 

«

Use caution to prevent any foreign objects from entering the housing.

 

«

Do not use in wet locations or in areas where moisture or condensation 

can be expected.

 

«

Do not touch during power-on, and immediately after power-off. Hot 

surfaces may cause burns.

CONNECTION AND OPERATION INSTRUCTIONS

PSDR095W

AC 100-240V

PSDR030W

Power Supply

L

N

24-28V

+ _ _

24V  1.3A

DC on

0.89

(22.5)

2.95

(75.0)

3.58 (91.0)

DIN-Rail

Depth

 DIMENSIONS  In inches (mm)

PSDR030W

Power Supply

N L

AC 100-240V

PSDR060W

_ _

+ +

24V  2.5A

DC on

24-28V

DIN-Rail

Depth

1.77 (45.0)

2.95

(75.0)

3.58 (91.0)

0.82

(20.8)

0.47

(12.1)

1.02

(26.0)

0.37

(9.5)

PSDR060W