Safety Requirements and Regulations

· 

Electric  fences  shall  be  installed  and  operated  so  that  they  cause  no  electrical  hazard  to  persons,
animals or their surroundings. Electric fence constructions, which are likely to lead to entanglement of
animals or persons, shall be avoided.

· 

An electric fence shall not be supplied from more than one energiser or from independent fence circuits
of the same energiser.

· 

The gap between two separate electric fences with different energisers shall be at least 2m.

· 

If this gap is to be closed, this should be affected by means of a electrically non conductive material.

· 

Barbed or razor wire shall not be electrified by an energiser.

· 

Any  part  of  an  electric  fence  which  is  installed  along  a  public  path  or  highway  shall  be  identified  by
warning signs (p/no 33020) securely fastened to the fence posts or firmly clamped to the fence wires at
intervals recommended to be of approximately 10 metres to 50 metres, but not exceeding 90 metres.
The  warning  signs  shall  be  at  least  100mm  x  200mm.  The  background  colour  of  both  sides  shall  be
yellow. The inscription shall be black and shall be the substance of TAKE CARE - ELECTRIC FENCE.
The inscription shall be indelible, inscribed on both sides and have a height of at least 25mm.

· 

Except  for  low  output  battery  operated  energisers,  the  energiser  earth  electrode  shall  penetrate  the
ground to a depth of at least 1m.

· 

Connecting  leads  that  are  run  inside  buildings  shall  be  effectively  insulated  from  the  earth  structural
parts of the building. This may be achieved by using double insulated high voltage cable (p/no 31640).
Connecting leads that are run underground shall be run in a conduit of insulating material.

· 

Care  shall  be  taken  to  avoid  damage  to  the  connecting  leads  due  to  the  effects  of  animal  hooves  or
tractor wheels sinking into the ground.

· 

Connecting leads shall not be installed in the same conduit as the mains supply wiring, communication
cables or data cables.

· 

Connecting  leads  and  electric  fence  wires  shall  not  cross  above  overhead  power  or  communication
lines.

· 

Crossings  with  overhead  cables  shall  be  avoided  wherever  possible.  If  such  a  crossing  cannot  be
avoided, it shall be made underneath the power line and as nearly as possible at right angles to it.

· 

If connecting leads and electric fences are installed near an overhead power line the clearances shall
be:
1. Power Line Voltage: Under 1000 volts - Clearance: 3 Metres
2. Power Line Voltage: 1000 - 33,000 volts - Clearance: 4 Metres
3. Power Line Voltage: Over 33,000 volts - Clearance: 8 Metres

· 

If  connecting  leads  and  electric  fence  wires  are  installed  near  an  overhead  power  line,  their  height
above ground shall not exceed 2m. This height applies either side of the orthogonal projection of the
outermost conductors of the power line on the ground surface, for a distance of - 2m for power lines not
exceeding 1000V - 15m for power lines exceeding 1000V.

· 

A distance of 10m shall be maintained between the energiser and any other earth system such as the
household supply system protective earth or the telecom system earth.

· 

A warning sign as described earlier, shall be fitted to every point where persons may gain ready access
to the conductors.

· 

Where an electric animal fence crosses a public pathway, a non-electrified gate shall be incorporated in
the electric fence at that point or a crossing by means of stiles shall be provided.

· 

At any such crossing, the adjacent electrified wires shall carry warning signs as described earlier.

Please retain instructions for future reference.

SX250

Solar Powered Energiser

Stockshop (L.E.) Ltd, Lodge Trading Estate, Broadclyst, Exeter, Devon, EX5 3BS

Tel: 01392 460077 Fax: 01392 460966 Email:

[email protected]

www.stockshop.co.uk

Summary of Contents for SX250

Page 1: ...to the effects of animal hooves or tractor wheels sinking into the ground Connecting leads shall not be installed in the same conduit as the mains supply wiring communication cables or data cables Connecting leads and electric fence wires shall not cross above overhead power or communication lines Crossings with overhead cables shall be avoided wherever possible If such a crossing cannot be avoide...

Page 2: ...p to 5km of single strand wire fencing 2 5km multi wire fence or 1 net Should you experience any problems with the operation of your unit please check the following 1 Is the Pulse Light flashing 2 If it is turn the unit off and disconnect the fencer from the fence Using a fence tester P no 33000 connect the tester between the HT clip and the earth clip turn the fencer on you should get a reading i...

Page 3: ...p to 5km of single strand wire fencing 2 5km multi wire fence or 1 net Should you experience any problems with the operation of your unit please check the following 1 Is the Pulse Light flashing 2 If it is turn the unit off and disconnect the fencer from the fence Using a fence tester P no 33000 connect the tester between the HT clip and the earth clip turn the fencer on you should get a reading i...

Page 4: ...to the effects of animal hooves or tractor wheels sinking into the ground Connecting leads shall not be installed in the same conduit as the mains supply wiring communication cables or data cables Connecting leads and electric fence wires shall not cross above overhead power or communication lines Crossings with overhead cables shall be avoided wherever possible If such a crossing cannot be avoide...