55
1-WARNINGS AND WARRANTY CONDITIONS
Technical Dept. - All rights reserved - Reproduction prohibited
INFORMATION
•
If there are any issues, contact the retailer or a qualified technician authorised by RED. In the event of a repair, request the use of
original spare parts.
•
Only use types of fuel recommended by RED (for Italy, pellets with a 6 mm diameter and pellets with a 6-8 mm diameter for other
European countries), which must only be loaded with an automatic feed system.
•
Periodically check and clean the smoke outlet duct (connection to the flue).
•
Accumulated unburnt pellets in the burner after a series of failed ignitions must be removed before lighting it again.
•
The pellet stove is not a cooking appliance.
•
Always keep the cover of the fuel tank closed.
•
Keep this instruction manual, which will be an integral part of the stove for the whole of its service life. If the product is sold or
transferred to another user, ensure the manual is also handed over.
•
If lost, contact RED or the authorised dealer to request a copy.
INTENDED USE
The product only works with wood pellets and must be installed indoors.
PRODUCT PERFORMANCE CHECKS.
All our products undergo ITT TESTS carried out by a notified laboratory (system 3) and in accordance with (EU) regulation number
305/2011 “Construction products”, according to standard EN 14785:2006 (pellets) and “Machinery Directive” EN 303-5 (boilers).
In the case of tests for any market surveillance or inspections by third parties, please consider the following warnings:
•
to reach the declared performance levels, the product must perform an operating cycle of at least 15/20 hours beforehand
•
use the average draught of the combustion smoke specified in the “technical product features” table
•
the type of pellets used must comply with current EN ISO 17225-2 regulations
•
the amount of fuel may vary according to the length and calorific value of the fuel. This may require some adjustments to stay in line
with the hourly consumption specified in the “technical product features” table. A1 pellets ensure an overall calorific value within
tight margins compared to the test pellets used. However, size considerably influences performance, so on average it must not be
less than 24 mm long and with a 6mm diameter
•
in the case of a wood-burning product, check the correct residual moisture content of the fuel, which must not be less than 12% or
more than 20%. As the moisture increases, different combustion air settings are required. The settings are to be carried out via the
combustion air register, thereby modifying the mixture between primary and secondary air.
•
it is necessary to check the operation of devices that can affect performance (for example air fans or electrical safety devices) in case
of damage due to handling.
•
maximum performance can be achieved at the maximum flame and ventilation power.
•
strictly comply with the withdrawal points specified in regulations both in terms of emissions and temperature.