13 - MAINTENANCE AND CLEANING
CLEANING THE SMOKE EXPULSION SYSTEM AND GENERAL CHECKS
Clean the smoke outlet system, especially around the “Tee” fittings, elbows and any horizontal sections of the smoke duct.
For information on periodically cleaning the flue, contact a skilled chimney sweep.
If necessary, order new replacement gaskets
from the retailer or contact an authorised service centre to carry out the operation.
ATTENTION:
The frequency with which the smoke outlet system must be cleaned depends on the use of the boiler and the type
of installation.
We recommend relying on an authorised service centre for end-of-season cleaning and maintenance. They will carry
out all of the previously mentioned work and make a general check of the stove’s components.
SHUTDOWN (end of season)
At the end of each season, before switching the product off, it is recommended to remove all the pellets from the tank with a vacuum
cleaner with a long pipe.
We recommend removing the unused pellets from the tank because it can retain moisture. Disconnect any combustion air ducting that
can lead moisture inside the combustion chamber but, above all, ask the specialised technician to refresh the paint inside the combustion
chamber with the special silicone spray paints (available at any store or Technical Assistance Centre) during the necessary annual end of
season scheduled maintenance operations. This way the paint will protect the inner parts of the combustion chamber, blocking any type
of oxidative process.
When not in use the appliance must be disconnected from the mains power supply. It is recommended to remove the
power cable for additional safety, especially in the presence of children.
The service fuse may have to be replaced if the control panel display does not switch on when the product is switched on again by pressing
the main switch on its side.
There is a fuse compartment on the back of the product, under the power socket. After having disconnected the plug from the socket, use
a screwdriver to open the cover of the fuse compartment and, if necessary, replace them (3.15 A delayed).