POLO 15W LED
Emergency Bulkhead with
Microwave Sensor
Installation Instructions p.4
For models: POL15LEDEMS
Red Arrow Trading
Elsworth House, Herries Road South, Sheffield, S6 1QS
T:
0800 195 0006
F:
0870 043 3946
E:
www.redarrowtrading.com
Positioning
•
The luminaire with detector should be sited so that the occupants of the room fall inside the detection patterns shown
in the appropriate diagram below.
•
The diagram is based on a ceiling mounting height of two and a half metres. Note that the lower the sensor is
installed, the smaller the detection range will be.
•
If wall mounted, the detection zone will vary depending on the surroundings but perpendicular reach will be at least
ten metres.
•
The area closest to the sensor & also the
area more perpendicular to the sensor will
have higher sensitivity.
•
The distance quoted are approximate & may
vary depending on surroundings.
•
Avoid direct sunlight entering the sensor.
•
Do not site within one metre of forced air
heating or ventilation.
•
Do not fix to a vibrating surface.
•
Avoid metallic objects directly in front of
the sensor head.
•
These sensor kits are capable of switching
/ controlling more than one luminaire in a
‘master & slave’ set up. This is done by
linking non-sensored fittings (slaves) to the
one with the sensor fitted (master) using the
live output from the sensor.
NOTE!
DO NOT link other fittings containing
MW sensors together in this way, as it can
cause false triggering of the sensors.
Settings
•
The following adjustments can be made using the three dials located on the sensor
unit. DISTANCE, TIME and LUX are adjustable via three rotatable dials.
1.
DISTANCE
Rotate the dial to control the diameter of the detection pattern, from one metre
minimum (fully anti-clockwise) to ten metres maximum (fully clockwise). The LED
setting indicator will flash to indicate the setting selected, e.g. ten flashes = ten
metres diameter.
2.
TIME
Rotate the dial to control the length of time the luminaire will stay on after occupancy
has ceased. From ten seconds minimum (fully anti-clockwise) to 30 minutes maximum
(fully clockwise).
DISTANCE TIME LUX
MAX MIN
MAX MIN
MAX MIN
• • • •
• •