22W LED Emergency Wilson
Bulkhead with Microwave
Sensor Corridor Function
Installation Instructions P.5.
For models: WIL22LEDEMSCF
T:
0800 195 0006
F:
0870 043 3946
E:
www.redarrowtrading.com
T:
0800 195 0006
F:
0870 043 3946
E:
www.redarrowtrading.com
Red Arrow Trading
Elsworth House, Herries Road South,
Sheffield, S6 1QS
Guarantee
This product is guaranteed for a period of 2 years from the date of purchase. The guarantee is invalid in the case of improper use, tampering, removal of the Q.C. date label, installation
in an improper working environment or installation not according to the current edition of the I.E.E. Wiring Regulations (BS7671). The guarantee is also invalidated if the luminaire has
been Mega tested. Should this product fail during the guarantee period it will be replaced free of charge, subject to correct installation and return of the faulty unit. We do not accept
responsibility for any installation costs associated with the replacement of this product. We reserve the right to alter specifications without prior notice.
Product complies with
all relevant European
standards
Product is suitable for
mounting on flammable
material
F
Fault - Load does not go off
•
Ensure that the area is left unoccupied for longer than the selected timer setting.
•
Make sure that the sensor is not adjacent to circulating air, heaters or lamps.
•
If the unit “false triggers” reduce the SENSITIVITY level to narrow the area of detection (rotate dial anti clockwise)
•
Ensure luminaire is not connected in parallel with other luminaires containing MW sensors
MAINTENANCE
•
Cleaning should be carried out at regular intervals so as not to impair photometric performance or thermal safety of
the luminaire.