4
Options
16 / 24
BAL_K32_K42_M_EN_1V1_REC_121-006454677
Unlocking the turnstile lock
– Pull the bow handle.
– Turn bow handle to the right until it reaches the stop
and release.
Reset turnstile lock
– Turn bow handle to the left.
– Release bow handle, the bow handle must retract
downwards.
4.4.3
Turnstile bar-bolt lock
The turnstile can be locked with a bar-bolt lock, integrated in the door frame profile. By rotating the
profile cylinder together with the ceiling construction, and/or additionally with a fitted socket integrated
in the floor.
4.4.4
Turnstile corner lock
The turnstile can be locked with a corner lock, at the bottom of the door frame profile. By rotating the
integrated profile cylinder with a fitted socked integrated in the floor.
4.5
Night shield variations
4.5.1
Manual night shield
Night shield with mechanical bar-bolt lock or hook bolt lock
The night shield can be locked and unlocked with profile cylinder locks integrated in the door frames.
If the night shield is in locked position, then it must be unlocked and completely pushed open manu-
ally.
Then the operating mode of the door can be selected.
4.5.2
Night shield - deadman
CAUTION
Night shield crushing danger
a) Fingers or hands getting crushed, sheared or pulled in
ð
To avoid crushing, the operator must have a clear view of the night shield during the OPENING
and CLOSING process.
NOTICE
If the night shield is manually locked (i.e. with a bar lock), then please ensure that the night
shield wings are manually unlocked before using the key reversing switch.
Switch example
It can be operated with the key reversing switch.
Opening process:
the night shield is opened by turning the key reversing switch to the right
(see arrow direction) and holding the position. If the night shield is locked electrically, then it
will simultaneously unlock. The opening process will stop when the key reversing switch is
no longer being turned or held. The opening process will resume by turning the key to the
right again and holding the position.
Closing process:
the night shield is closed by turning the key reversing switch to the left
and holding the position. The closing process will stop when the key reversing switch is no
longer being turned or held. If the night shield is locked electrically, then it will lock automat-
ically in the locked position.
Collision detection:
if a night shield wing hits an obstacle during the opening or closing pro-
cess, the night shield will stop and remain stopped. The next opening or closing process will
start when the key reversing switch is turned and held in position again.