4
Options
14 / 24
BAL_K32_K42_M_EN_1V1_REC_121-006454677
4
Options
4.1
Lighting control
The lights can be turned on or off via an on-site light switch or over the building control centre.
4.2
Speed control
Dependent on the configuration an electronic or hydraulic speed control is installed in the drive unit
for safety reasons. This prevents the turnstile from spinning too fast when passing through the re-
volving door too quickly. The limitation of rotation speed can be adjusted on the speed control.
4.3
Foldable turnstile wings and/or foldable drum walls
The system can be equipped with hinged turnstiles and / or, in case of a three-wing system, with
hinged drum walls.
If a turnstile leaf and/or a drum wall is manually opened, this condition is signaled to the system con-
trol via a monitoring switch. At the same time, the turnstile movement is immediately stopped in all op-
erating modes and the system control is switched off.
To continue the set operating mode, all turnstile leaves and/or the drum walls must be manually re-
engaged in their original position.
The turnstile starts automatically and continues the set operating mode.
Folding turnstile leaves are held in position by electrical or mechanical leaf locks.
Folding drum walls are held in position by magnets.
Basic positions
Inside
K32
K42
Outside
Folding positions
Inside
K32
K42
Outside