Repairs
4
record sliding door system 20
Article no. 102-020.110.805
page 11
No. Display text
Type
Res Comments and possible troubleshooting
52
No run param.
X
Door must be calibrated (perform teach-in run).
53
Interrupt. mot. 1
X
Motor is not plugged in. Motor is faulty.
Afterwards reset.
54 W
Calibrating run
X
Warning message:
Calibration run is perforned.
55
Power failure
No mains supply.
Door works in battery service provided that there is a battery
and not "Basic escape route" has been configured.
57
Interrupt. mot. 2
RED /
DUO
X
2nd motor is not plugged in. Motor is faulty.
Afterwards reset.
59
ELS > 60 sec. active
Light barriers disconnected and door remains open.
Check that safety barriers are not covered or extremely dirty.
Door can be locked with
59
SIS > 60 sec. active
X
Door does not close.
Control safety element. Are ELS covered?
Door can be locked with
60
EEPROM defective
X
Load factory settings. 9 light pulses with MFT and reset within
10 seconds. Afterwards language selection has to be displayed
on BDE-D. Attention! All programmings are reset.
Reconfigure door.
Replace control unit if door still fails to function.
61
SSK > 60 sec. active
Key-operated contact stays active. Door remains open.
Control SSK-switch and wiring/connections.
Door can be locked with
62
BDE no priority
BDE is locked e.g. by a clock timer on input SURV/SURA ac-
cordingly configured. On RED installations, door is locked with
BDE-V.
88
Diff. parameters
RED
X
With RED, different programmes.
CPU1 and CPU2 must have the same software.
92
STG relay defect.
X
Change control unit.
93
Overvoltage 24V
X
Wiring error. Check connections.
96
EEPROM void
X
Load factory settings. See error 60.
97 W
Maintenance time
exceeded
X
Warning message:
Actual value = 105% of target value of cycles or operating
hours.
Acknowledge message. Alarm is reset for 13 days.
Inform after-sales service and have installation serviced.
98 W
Maintenance due
X
Warning message:
Actual value = 95% of target value of cycles or operating hours.
Repeat at 100%.
Acknowledge message. Alarm is reset for a short time.
Inform after-sales service and have installation serviced.
100
Check motor cable
RED /
DUO
Control all motor cables.
Rotating direction of jumper JP4 is wrong. Jumper for rotating
direction does not function with RED and DUO. Set rotating
direction with connecting clamp.