   General Hot-Shot

Operating Instructions

 

 

Model 320

 (For use with Copper and Iron Pipe) 

Y

our Hot-Shot is designed to give you

years of trouble-free, profitable service.  

However, no machine is better than its 

operator.  We therefore suggest you read 

these instructions through carefully before 

using your machine on the job.  This will 

enable you to operate the Hot-Shot more 

efficiently and more profitably.  Failure to 

follow these instructions may cause 

personal injury to operator or damage to 

equipment. 

SAVE THESE INSTRUCTIONS! 

B

efore

 

connecting  the  cables

.    Make  both 

pipe

 

connections 

before 

plugging 

unit 

into 

receptacle.

 

Make  sure  all  connections  are  tight  to 

prevent arcing

 

at the clamps.

  Loose connections also 

get  hot  and  reduce  current  flow.    Caution:    Uncoil 

the  cables.

 

Do  not  leave  any  cable  coiled  up  or 

placed on steel

 

objects as the heating in the pipe will be 

reduced.

Содержание Hot-Shot 320

Страница 1: ... you to operate the Hot Shot more efficiently and more profitably Failure to follow these instructions may cause personal injury to operator or damage to equipment SAVE THESE INSTRUCTIONS Before connecting the cables Make both pipe connections before plugging unit into receptacle Make sure all connections are tight to prevent arcing at the clamps Loose connections also get hot and reduce current f...

Страница 2: ...er entering a power tool will increase the risk of electric shock 4 Do not abuse the cord Never use the cord to carry the tools or pull the plug from an outlet Keep cord away from heat oil sharp edges or moving parts Replace damaged cords immediately Damaged cords increase the risk of electric shock 5 When operating a power tool outside use an outdoor extension cord marked W A or W These cords are...

Страница 3: ...about 10 minutes if the connections are properly made Since copper pipe will not heat as fast as steel pipe allow about a 30 percent longer thawing time See Chart Features The Hot Shot 320 puts out 320 amps yet pulls only 14 amps It can clear 1 2 to 1 1 2 pipes up to 100 ft long The Hot Shot 400 can clear 1 2 to 1 1 2 pipes up to 175 ft long The Hot Shot 400 features a High Low switch to allow the...

Страница 4: ...Has the thermal protector tripped Is there a rubber coupling in the line Is there plastic pipe in the line Has the ice pushed the joints apart 2 Cables get warm Pipe does not thaw Are clamps on pipe not on curb cover Are the pipes clean under the clamps Are cables sized properly Larger cables must use larger wire size 3 Cables get hot Pipe does not thaw Is there water pressure in pipe Is the sourc...

Отзывы: