![Recom RCM-10-TP-D User Manual Download Page 32](http://html.mh-extra.com/html/recom/rcm-10-tp-d/rcm-10-tp-d_user-manual_1426765032.webp)
32
8. Technical Parameters
Model
RCM-
4-TP-D
RCM-
5-TP-D
RCM-
6-TP-D
RCM-
8-TP-D
RCM-
10-TP-D
RCM-
12-TP-D
RCM-
15-TP-D
RCM-
17-TP-D
RCM-
20-TP-D
RCM-
25-TP-D
DC Input
Start-up Voltage (V)
180
180
180
180
180
180
180
180
180
180
Max. DC Input Voltage (V)
1,100
1,100
1,100
1,100
1,100
1,100
1,100
1,100
1,100
1,100
Min. DC Voltage (V)
150
150
150
150
150
150
150
150
150
150
Rated DC Input Voltage (V)
620
620
620
620
620
620
620
620
620
620
MPPT Voltage Range (V)
160-1000
Full power MPPT Voltage
Range (V)
200
~850
240
~850
280
~850
370
~850
470
~850
560
~850
470
~850
400
~850
470
~850
585
~850
No. of MPP Trackers
2
2
2
2
2
2
2
2
2
2
No. of DC Inputs per MPPT
1/1
1/1
1/1
1/1
1/1
1/1
1/2
2/2
2/2
2/2
Max. Input Current (A)
15/15
15/15
15/15
15/15
15/15
15/15
15/30
30/30
30/30
30/30
Max. Short-circuit
Current (A)
20/20
20/20
20/20
20/20
20/20
20/20
20/40
40/40
40/40
40/40
Backfeed current
to the array (A)
0
0
0
0
0
0
0
0
0
0
AC Output
Rated Output Power (KW)
4
5
6
8
10
12
15
17
20
25
Max. Output Power (KW)
4.4
5.5
6.6
8.8
11
13.2
16.5
18.7
22
25
AC output rated apparent
power (KVA)
4
5
6
8
10
12
15
17
20
25
Max. Apparent Power (KVA)
4.4
5.5
6.6
8.8
11
13.2
16.5
18.7
22
25
Rated Output Voltage (V)
3L/N/PE, 230/400V
Rated AC Frequency (Hz)
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
AC output rated current (A)
5.8
7.3
8.7
11.6
14.5
17.4
21.7
24.6
29
36.2
Max. Output Current (A)
6.7
8.4
10
13.3
16.5
20
25
28.4
31.9
39
The measured Inrush
current (A)
7A@4ms
8.5A@4ms
Max. output
fault current (A)
33
33
33
33
40
40
66
66
76
76
Max. output overcurrent
protection (A)
33
33
33
33
40
40
66
66
76
76
Power Factor
0.8 leading …0.8 lagging
Max. total harmonic
distortion
< 3% @Rated Output Power
DCI
< 0.5%In
Summary of Contents for RCM-10-TP-D