11 Technical specifications
Application
Data
Supply voltages
230 V AC
±10% 50-60 Hz
110 V ... 120 V AC ±10% 50-60 Hz
Power consumption: max. 53 VA
Back-up fuse: max. 4 A
26 V … 28 V DC
Power consumption: max. 30 W
Back-up fuse: max. 4 A
A UL class 2 power supply unit is recommended for the
operation of the filter controller with extra low voltage.
Signal inputs
24 V DC, operate ensuring isolation
Signal output
Relay outputs, max. 2 A, 250 V
or 1 A, 30 V DC
Control outputs for valves
For valves with a rated voltage of 24 V DC,
can be expanded to 128 outputs,
Output power in pulse mode 42 Watt
Outputs for expansion
modules
Supply voltage and pulse wires to the expansion modules
Fuses
F1 (230 V):
M 0.2 A 250 V / 5 x 20 mm
Type Bell 5MT 200 mA (ESKA UL 521.010)
F2 (110 V):
M 0.3 A 250 V / 5 x 20 mm
Type Bell 5MT 300 mA (ESKA UL 521.012)
Extra low voltage: Fusing via PTC resistor
Electrical connections
Screw terminals
Permissible wire gauge
single-wire: 22 ... 16 AWG / 0.5 ... 1.5 mm²
Flexible:
22 ... 16 AWG / 0.5 ... 1.5 mm²
Cable glands
Size
Sealing range
Cord diameter
Installation
range
torque
M16x1.5
5 … 10 mm
5.6 ... 10 mm
2.0 Nm
M20x1.5
8 … 13 mm
9 ... 13 mm
2.7 Nm
M25x1.5
11 … 17 mm
13 ... 17 mm
5.0 Nm
Temperature range
-20°C to +50°C
Degree of protection
Housing IP-66 not evaluated by UL / Type 5
Installation torque of cover screws: 1,5 Nm
Dimensions
See chapter 3 “Assembly”
Weight
approx. 0.8 kg
Installation height