28
Note:
A change in the room temperature (Temperatures/Heating temperature menu) has influence on the
weather characteristics that adapts to new requirements.
Room sensor - adjustment
4
The controller will automatically correct the heating temperature after detecting differences between the room
temperature set value and the sensor reading. The adjustment allows increasing the influence of the sensor on
the CH temperature changes (values greater than zero) or decreasing it (negative values).
For underfloor
heating, it is recommended to set the value of 60%.
Room sensor - calibration
5
Due to cable length and sensor execution precision, the temperature indication may differ from the actual
values by a few degrees. Using the knob allows setting the correct value by carrying out sensor calibration. The
corrected value is displayed in the upper right corner of the display.
AUTO temperature - SUMMER/WINTER
This parameter is used only when the Service turns on the operation with the external sensor. Moreover, the
user must select the AUTO MODE (menu - Advanced/CH circuit/Summer/Winter/AUTO mode). When the
external temperature exceeds the set value, the regulator switches to the SUMMER MODE. When the
temperature drops - it switches to the WINTER MODE. (See the above description - SUMMER/WINTER MODE).
CH program
6
The CH program operates on a similar basis as the HW described below (see
The weekly CH program
). The time
interval marked with a black rectangular means heating operation with the set temperature. During the
remaining time, the regulator will reduce the temperature according to the
Heating temperature decrease
setting
.
4
5
This option is available only for the „circuit control” setting on the position:
ROOM TIME +EXTERNAL TIME
6
This option is available only for the „circuit control” setting on the position:
MANUAL
and
ROOM TIME
+EXTERNAL TIME