EN
14
2. Connect
the
black
lead
of
the
K-type
thermocouple to the COM terminal.
3. Set the rotary switch to °C position.
4. The temperature will be displayed.
5. Maximum measurement of the temperature is
250°C / 482°F.
Continuity test
1.
Connect the red test lead to the VΩmA terminal.
2. Connect the black test lead to the COM terminal.
3. Set the rotary switch to the
position.
4. Connect the test leads to a measured circuit. If
the resistance is lower than 30 Ω, the buzzer will
buzz.
Battery test (model RB-33B only)
1.
Connect the red test lead to the VΩmA terminal.
2. Connect the black test lead to the COM terminal.
3. Set the rotary switch to the proper range,
according to the measured battery.
4. Connect the test leads to the battery.
5. Result will be displayed.
Generator function (model RB-33D only)
1.
Set the rotary switch to position
.
2. Test signal 50 Hz will appear between terminals
VΩmA and COM. Input voltage is approx. 5 V
with impedance 50 KΩ.
Overload protection: for 15 seconds in max. 220 V.