EN
12
13. Do not tamper with devices internal circuits. This
may lead to accuracy decrease or damaging the
device.
14. The device is intended for indoors use only.
15. Take out the batteries, if the device is not going
to be used for a long time..
PRODUCT DESCRIPTION
1.
Display
2. Display backlight button
3. Measurement hold button
4. Rotary switch
5. Connection terminals
OPERATION
AC and DC measurement
1.
Connect the red test lead to the VΩmA terminal.
2. Connect the black test lead to the COM terminal.
3. Set the rotary switch to proper voltage range.
4. Connect the test leads to a measured circuit.
5. Turn on the circuits power. The voltage and
polarization will show on the display.
*If the range is not known, set the range to highest and
gradually lower it, until getting the accurate measurement.
DC current measurement
1.
Connect the red test lead to the VΩmA terminal. If
the measurement will be in 200 mA - 10 A range,
connect the red test lead to the 10 A terminal.
2. Connect the black test lead to the COM terminal.