6
INSTALLATION INSTRUCTIONS
(continued)
FLUE TERMINATION LOCATION
This section is used to determine where your flue termination will be located.
•
Flue terminations shall not be recessed in walls or sidings.
•
EXTREMELY IMPORTANT:
In heavy snow areas take extra care to prevent blocking
flue termination with snow removal equipment.
•
Flue gases exiting flue terminals are very hot and must not be restricted to assure fireplace
combustion is not affected.
•
Do not place, build any obstruction, plant any bushes or for any reason attempt to conceal
the flue termination. To do so will affect the operation of the fireplace and may be hazardous.
•
This unit must always vent directly to outdoors.
•
Some flue configurations may not be suitable for installation in ice / snow environments, please
refer to Glen Dimplex Australia for installation suitability.
•
XLC flue configurations are designed to release condensation and may not be suitable for ice /
snow environments.
Condensate disposal
Where possible the condensate drainage pipe should terminate at a suitable foul water discharge
point, eg waste drain point washing machine waste point etc.
The HepVO waterless trap should be installed where access can be maintained.
A P-trap can be used as an option instead of the HepVo waterless trap.
Do not discharge condensate onto walkways, electrical connections, earth stakes, copper pipes,
waterways, ponds etc.
POLY PRO GENERAL INSTALLATION REQUIREMENTS
Refer to specific setups for detailed installation guides.
Poly Pro flue systems meets Flame spread/ Smoke ratings <25/<50 (per UL-723 ASTM E-84 and
ULC-S102) when used in conjunction with the below noted materials.
•
3m Fire barrier Plenum wrap 5A+
•
Unifrax FyreWrap 0.5 Plenum insulation
•
Knauf Insulation
– Atmosphere Duct wrap with ECOSE
Use soapy water to lubricate gaskets and tubes.
DO NOT USE petroleum-based lubricants.