INSTALLATION INSTRUCTIONS
(continued)
32
WALL TERMINAL WITH CONDENSATE MOUNTING
Locate terminal on wall and predrill mounting
holes where required.
Markout the required penetration area. Cutout the
area in wall for the flue pipes and condensate
drain. (NOTE - Access to rear of terminal may be
required to assemble flue) Where access is not
available a single large cutout is required for the
flues and the condensate drain.
Cut inlet air tube. Flue must extend a minimum of
50mm past the exit face of wall.) It is
recommended that the intake tube is cut slightly
longer and pushed back into wall upon fixing of
wall terminal. Allow flue movement between
terminal and last intake flue hanging clip.
Attach intake flue using the self tapping screw.
Ensure condensate drain retaining clamp is tight.
Push terminal into approximate position and affix
onto wall