11
Check for leaks at these locations
!
!
WARNING
Before using this outdoor fire column, make
WARNING
Failure to inspect this connection or
sure you have read, understand and are following all
information provided in the Important Safety Information
section of this manual. Failure to follow those instructions
can cause death, serious injury or property damage.
follow these instructions could cause a fire or an
explosion, which can cause death, serious bodily
injury, or damage to property.
Prior to each gas fire column operation, check the valve
assembly for evidence of excessive abrasion or wear
though the access panel on the side of the base. Replace
the access panel prior to operating fire column.
BURNER CONNECTIONS
Make sure all of the connections are tight. If your unit
was assembled for you, visually check all connections.
Please refer to diagram for proper installation.
If any part appears to be incorrect please contact Real
Flame at 1-800-654-1704 for assistance.
CHECKING FOR LEAKS
Make a leak check solution by mixing 1 part dish
washing soap with 3 parts water in a spray bottle.
Make sure control knob is “OFF.” Then, attach the 1 lb
LP gas tank.
Spray leak solution on valve connections paying
particular attention to the areas indicated by arrows.
If any bubbles appear turn LP gas tank OFF,
reconnect and re-test. If you continue to see bubbles
after several attempts, disconnect LP gas source and
contact Real Flame at 1-800-654-1704 for assistance.
If no bubbles appear after one minute turn tank OFF,
wipe away solution and proceed.