17
Operating instructions
Peristaltic Pump RP Series
8.2 Commissioning
8.2.1 Testing prior to commissioning the pump
The following tests are to be carried out:
- Check that the shoes are correctly fitted and fastened.
- Check that the drive and the Pump Housing are properly
lubricated. The specially formulated lubricant can be obtained
from the authorized distributor.
- Only switch the pump on if the front cover has been properly
attached.
- Check that the mains voltage is suitable for the motor.
- Check that the thermal overload protection (not included in
the delivery scope) corresponds to the value specified on the
motor type plate.
- Confirm that pump has been properly earthed
- Connect the electric motor according to local applicable rules
and regulations. The electrical installation work must be carried
out by qualified personnel.
- Check that the optional electrical components are connected
and are working properly.
- Check whether the direction of rotation is correctly adjusted.
8.3 Correct installation of the pump
- Ensure that the pump has not been damaged during
transportation or storage. Immediately report any damage to
the supplier.
- Ensure that all the packaging has been removed.
- Check that the information printed on the identification plate
corresponds with the order.
- Check the operating instructions in order to ensure that the
flow values, pressures & power consumption of the motor do
not exceed rated values.
- Ensure that the hose is suitable for the fluid to be conveyed
and that it is not damaged.
- Make sure that the temperature of the liquid does not exceed
the recommended temperature range.
- Ensure that there is enough space for free airflow around the
motor.
- Ensure that no nearby objects or direct sunshine radiate
additional heat to the motor.
Summary of Contents for RP 10
Page 1: ...1 Operating instructions RP Series Peristaltic pump ALL THE HOSE PUMP YOU LL EVER NEED...
Page 44: ...44 Operating instructions Peristaltic Pump RP Series 11 5 Spare parts exploded view RP 60...
Page 46: ...46 Operating instructions Peristaltic Pump RP Series 11 6 Spare parts exploded view RP 70...
Page 50: ...50 Operating instructions Peristaltic Pump RP Series 11 8 Spare parts exploded view RP 80...
Page 52: ...52 Operating instructions Peristaltic Pump RP Series 11 9 Spare parts exploded view RP 100...
Page 56: ...56 Operating instructions Peristaltic Pump RP Series 13 Declaration of Conformity...
Page 62: ...AHQ IOM EN 0833 0920 www realaxpumps com ALL THE HOSE PUMP YOU LL EVER NEED...