13
Operating instructions
Peristaltic Pump RP Series
5
CONSTRUCTION
The pump housing is closed off with a bolted front cover in order to avoid
the risk of injury.
The motor serves to drive the rotor. Two shoes attached to the rotor serve
to press the pump hose against the pump housing.
The rotary movement of the rotor alternately presses and releases the
shoes against the pump hose. This serves to suck the media and convey it
into the metering line.
Fig. 1: Diagram of functional principle
1. Pump housing | 2. Rotor | 3. Shoes | 4. Hose
4.3 Identification of the gearbox (b)
The gearbox has an identity plate with the model, serial number and
manufacturer’s details as well as information relevant to its’ function such
as reduction ratio.
4.4 Identification of the electric motor (C)
The motor has an identity plate with the model, serial number and
manufacturer’s details as well as information relevant to its’ function such
as electric power.
Summary of Contents for RP 10
Page 1: ...1 Operating instructions RP Series Peristaltic pump ALL THE HOSE PUMP YOU LL EVER NEED...
Page 44: ...44 Operating instructions Peristaltic Pump RP Series 11 5 Spare parts exploded view RP 60...
Page 46: ...46 Operating instructions Peristaltic Pump RP Series 11 6 Spare parts exploded view RP 70...
Page 50: ...50 Operating instructions Peristaltic Pump RP Series 11 8 Spare parts exploded view RP 80...
Page 52: ...52 Operating instructions Peristaltic Pump RP Series 11 9 Spare parts exploded view RP 100...
Page 56: ...56 Operating instructions Peristaltic Pump RP Series 13 Declaration of Conformity...
Page 62: ...AHQ IOM EN 0833 0920 www realaxpumps com ALL THE HOSE PUMP YOU LL EVER NEED...