(although most unlikely) incorporation of
particles from the hose into the product being
pumped. This can be achieved by means of
filtration, a hose rupture alarm or other means
suitable for the respective process.
CIP cleaning
- In the event of CIP cleaning, it is necessary to
obtain information from the manufacturer
about correct installation of the pump (a
special installation is required) as well as
regarding the compatibility of the cleaning
agents with the pump hoses and the hydraulic
connections.
- Cleaning should be undertaken at the
recommended maximum temperature.
Direction of rotation/flow direction
Possible consequence: material damage,
destruction of the unit.
- The pump’s direction of rotation in relation
to the desired flow direction must be checked
prior to every start.
Disconnect the pump from the mains
Possible consequence: personal injury.
- Work may only be carried out on the pump
after it has previously been switched off and
disconnected from the mains.
Environmental influences
Possible consequence: material damage up to
destruction of the unit.
- The device is suitable for outdoor operation
once it is covered and protected from rain and
direct sunlight. Ambient conditions must also
be respected
(see section 8.1).
- Take suitable measures to protect the device
from environmental influences such as:
UV rays | moisture | frost | etc.
!
!
!
Summary of Contents for APY
Page 1: ...Operating instructions APY Series Peristaltic pump ALL THE HOSE PUMP YOU LL EVER NEED...
Page 25: ...25 25 Troubleshooting Spare parts End of life...
Page 30: ...Operating instructions Peristaltic Pump APY Series 30 10 2 Spare parts exploded APY LAB Model...
Page 33: ...33 12 Declaration of Conformity K t d d W Z Wz W d Wz Z W d D d W W W...
Page 39: ...Operating instructions Peristaltic Pump APY Series 39...
Page 40: ...AHQ IOM EN 0971 0521 www realaxpumps com ALL THE HOSE PUMP YOU LL EVER NEED...