background image

Reverse Osmosis (R/O) 

or Well Water

If your water source is from a tested safe to drink 

well/ground water or has passed through a “Reverse 

Osmosis” system you may not have enough 

beneficial minerals in your water for the Water Ionizer 

to function at it’s full potential. 

However we have a solution for you.

Please use the included Mineral/Carbon Filter

Any Questions Call

1-888-601-5886

This filter will add back the beneficial minerals that 

your “R/O” or well water is missing. 

Carbon & Mineral Filter

NEED HELP CALL 1-888-601-5886

21

Owner’s Manual AquaIonizerPro.com Aqua Ionizer Deluxe Antioxidant Machine

Summary of Contents for AID9500A

Page 1: ...Read Carefully Before Initial Use Retain Manual for Future Reference Model AID9500A Owner s Manual Aqua Ionizer Deluxe Antioxidant Machine...

Page 2: ...18 5 Connect the Inlet Water Hose to the Faucet Diverter Valve 18 6 Check for Leaks 20 A R O Systems and Well Water 21 7 Plug In the Water Ionizer 22 FREE pH Kit 23 ORP Testers 23 Understanding the LC...

Page 3: ...ter Filter 1 Faucet Diverter Valve 1 Flexible Metal Spout 1 Dual Tread Faucet Connector 1 Pre Installed Inlet and Outlet Hose Water Filter 1 Mineral Carbon Standard Water City RO or Low pH Water Silic...

Page 4: ...dance with this product manual Water Ionizer Flexible Metal Spout Power Cord Inlet Water Hose Acidic Water Outlet Hose NEED HELP CALL 1 888 601 5886 Owner s Manual AquaIonizerPro com Aqua Ionizer Delu...

Page 5: ...urification source for water that does not meet these standards Attempting to use the water ionizer in this manner will void the warranty reduce the unit s performance shorten its operational life and...

Page 6: ...k and fire hazards Be sure the electrical plug is seated fully in the power outlet Do NOT bend pinch clamp place heavy objects upon modify or otherwise damage the unit s power cord or plug Do NOT plug...

Page 7: ...ll add back the benifical minerals the ionizer needs to function properly Any Questions Just call 1 888 601 5886 NEED HELP CALL 1 888 601 5886 If You have an R O System REVERSE OSMOSIS or low pH WELL...

Page 8: ...or mental capabilities nor by individuals with otherwise limited knowledge skills and abilities regarding the operation of electrical appliances in general and water ionizers in speciifc unless they h...

Page 9: ...Initial Drinking setting and consume only small amounts 8 to 16 ounces 0 25 to 0 5 liters per day Continue this practice for at least 2 weeks prior to advancing to your unit s higher pH value Daily Dr...

Page 10: ...health problems consult your local veterinarian before giving them alkaline water and or following any negative health reaction to the alkaline water Start them off slowly on Drinking setting and keep...

Page 11: ...ur specific plants Flushing Residual Water Because a certain amount of water remains trapped in your water ionizer s filters and tubing you should briefly drain this water off prior to each use In ord...

Page 12: ...ground fault circuit interrupter GFCI This appliance must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistanc...

Page 13: ...the maximum power usage when the unit s Cooking setting is engaged ionized water pH output is constant and rated inflow water temperature and total dissolved solids TDS are at their default value The...

Page 14: ...x 6 months to 1 Yr with normal usage Cleaning Cycles 1 After each use unit automatically cleans itself for 10 seconds by reversing positive and negative plate polarity 2 Every 40 liters 10 6 gal the u...

Page 15: ...ext page Please follow each of the following steps in order 1 Identify Required Connector s Attach Faucet Diverter Valve 2 Insert the Water Ionizer s Inner Carbon Filter 3 Pre Installed Inlet Outlet W...

Page 16: ...nthreaded i e those without screw on in connectors The type of faucet you have will determine whether you can attached the Faucet Diverter Valve directly to your faucet or which of the type of faucet...

Page 17: ...aucet pressing upward firmly then tighten bolts securely locking it on to faucet Next screw the Inner Faucet Thread Joint securely into the bottom of the 3 Bolt Faucet Connector Then screw the Faucet...

Page 18: ...ing gently with your finger and pulling up B Firmly grasp the water ionizer s Inner Filter Cover and twist it counter clockwise to open and gain access to the filter chamber C After unpacking the new...

Page 19: ...require the filter to be replaced more often If you notice an unusual odors or taste in your water replace the filter as necessary IMPORTANT VIDEO FOR HELP Installation Step 3 Note You may need to cut...

Page 20: ...ter Outlet Hose into the bottom valve Inlet Water Hose On Top Acidic Water Outlet Tube On the Bottom CAUTION Be sure that the Metal Spout and the white hoses for the source water IN and the acidic OUT...

Page 21: ...s out line allows the acidic water to flow out of the small spigot next to the larger spigot normal water flow is from the larger spigot This diverter when attached to the faucet end provides alkaline...

Page 22: ...here are no leaks from any of the hose connection points the Inner Filter Cover nor from anywhere else on the water ionizer This process will also flush any remaining air from the water filter C If th...

Page 23: ...our water for the Water Ionizer to function at it s full potential However we have a solution for you Please use the included Mineral Carbon Filter Any Questions Call 1 888 601 5886 This filter will a...

Page 24: ...solved Solids TDS and temperature of the source water as well as the flow rate through the water ionizer can all cause variations in the pH level of the water dispensed from your water ionizer For exa...

Page 25: ...Pro com Caution using store bought ORP Testers Many of these testers are designed for Fish Tanks and Swimming Pools only These NON Professional ORP testers are not designed to be accurate after 100 OR...

Page 26: ...flowing into the water ionizer E Purify Electrolyze Divide Monitor This active display confirms your water ionizer is progressing through various water filtration electrolysis and water separation sta...

Page 27: ...foliant removing dead cells and acts as an astringent which tightens the skin removes fine lines and wrinkles And because acidic water kills surface bacteria on the skin it also helps fight acne and b...

Page 28: ...preset selection D Once you re done dispensing water simply shut off your faucet and or the attached Faucet Diverter Valve Automatic Cleaning Function A Whenever the water ionizer is in any of the 4 a...

Page 29: ...tion is triggered after approximately every 10 5 gallons 40 liters of water have been dispensed B When Enhanced Cleaning is required a flashing Wash Indicator light will appear on the unit s LCD Note...

Page 30: ...tic Cleaning processes and then unplug water ionizer from the electrical outlet remove it from it s wall mount and place upright on the sink counter B Unscrew the Inner Filter Cover Then Remove the Ca...

Page 31: ...idic Water Outlet valve Reattach Water Inlet and Acidic Water Outlet Hoses and save the Stoppers for future use Alternative Method Remove the clip or rubber band from the Acidic Water Outlet Hose allo...

Page 32: ...However you can reduce the instances in which the cloudiness occurs by a lowering the pH level or b increasing the water flow rate through the unit Problem White particles begin to appear in your alk...

Page 33: ...H variance is more extreme you may want to move up or down to the next preset level to achieve the desired pH level Problem Acidic water seems to have an unusual smell or odor Solution DO NOT DRINK Th...

Page 34: ...ost of shipping the unit to the service facility However following repair or replacement RealSpirit USA will cover the cost of shipping the unit back to the consumer within the continental United Stat...

Page 35: ...ecognized P I P E or other certified contractor P I P E is the parent company of the National Inspection Testing and Certification Corporation known in the industry as National Inspection Testing Cert...

Page 36: ...Questions 1 888 601 5886 Aqua Ionizer Pro is a division of Real Spirit USA Inc 320 South Rock Blvd Suite 210 Reno NV 89502 Ph 888 601 5886 www AquaIonizerPro com help realspiritusa com...

Reviews: