background image

2

WARRANTY INFORMATION

The benefits provided to you under the following warranty are in addition to any other rights and remedies available to

you under the law.

1. Warranty

If:
(a) during the first 15 years from the date of purchase (Firebox Warranty Period), there is a defect in the firebox of

the Real Flame Gas Burner; or

(b) during the first 2 years from the date of purchase (Parts Warranty Period), there is a defect in the gas valves or

other parts of the Real Flame Gas Burner, 
due to improper workmanship or material, Real Flame will replace or repair the Real Flame Gas Burner without

charge.  Any replacement product is warranted only for the time remaining on the original Firebox Warranty

Period or the Parts Warranty Period as relevant.

2. Registration

You must register to receive the benefit of this warranty by completing the warranty registration on our website

(www.realflame.com.au) or completing and mailing the attached registration card within 30 days of purchase of

your Real Flame Gas Burner (or, if the Real Flame Gas Burner is fitted to a new home, within 30 days of the date

of settlement of purchase of such new home).

3. Exclusions

Real Flame is not obliged to replace or repair the Real Flame Gas Burner under clause 1 if: 

(a) it has been improperly stored, installed, connected, used, operated or repaired, or damaged, abused, tampered

with, altered (without our written approval), or not maintained in strict accordance with our installation and

operating instructions; or

(b) it has been installed in an outdoor setting.

4. Limit of Liability

The warranty provided under this warranty is limited to replacement or repair of the Real Flame Gas Burner only,

at our option. To the extent permitted by law, Real Flame excludes liability for consequential loss or any other

loss or damage caused to property or persons arising from any cause whatsoever, and damage arising from

normal wear and tear.

5. Claiming under the Warranty

In order to claim under this warranty you must, within the Firebox Warranty Period or the Parts Warranty Period

(as relevant), contact Real Flame, providing the original proof of purchase and the details below:

Supplier Name___________________________________________________________________________
Date Of Purchase / settlement of property if new home _________________
Model / Serial Number_______________________
This warranty does not cover the cost of claiming under the warranty or transporting the Real Flame Gas Burner to and

from the supplier.

Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a

replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage.

You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure

does not amount to a major failure.

If you would like to speak to someone about your Real Flame Gas Burner or claiming under this warranty, please

contact the Real Flame Service Warranty Desk on 1300 554 155.

Glen Dimplex Australia Pty Ltd ACN 69 118 275 460
Head Office: 1340 Ferntree Gully Road, Scoresby 3179
Telephone: (03) 8706 2000  Facsimile: (03) 876 2001

Summary of Contents for Magiglo 1000

Page 1: ...ATING MANUAL The Magiglo series of decorative fires are suitable to be installed into a masonry or approved prefabricated fireplace and are designed to operate with Natural and Propane gases only Appr...

Page 2: ...en installed in an outdoor setting 4 Limit of Liability The warranty provided under this warranty is limited to replacement or repair of the Real Flame Gas Burner only at our option To the extent perm...

Page 3: ...EGISTER OR EXHAUST SYSTEM DOES NOT ADVERSLEY AFFECT THE OPERATION OF THE APPLIANCE OR DRAUGHT OF CHIMNEY OR FLUE DO NOT MODIFY THIS APPLIANCE THIS APPLIANCE IS DESIGNED TO OPERATE WITH LUMINOUS FLAMES...

Page 4: ...g Procedure 13 Typical Type 1 Installation to existing chimney 14 Type 1 Installation into Victorian Federation grate 15 Typical Type 2 Installation of Prefabricated Fire Box into existing chimney 16...

Page 5: ...to test point 2 Adjust pilot pressure screw wind screw fully in then wind out 2 1 2 full turns for 400 540 750 models only 3 Adjust maximum burner pressure screw wind max pressure screw out 2 full tur...

Page 6: ...6 DIMENSIONS Magiglo 320 Burner PLAN RHS LHS B A C E FRONT D A B C D E 147 110 341 317 84 Magiglo 360 PLAN FRONT RHS LHS B A C D E A B C D E 199 110 210 360 155...

Page 7: ...7 DIMENSIONS Magiglo 400 Burner PLAN RHS LHS B A E FRONT D C A B C D E 201 103 433 328 148 Magiglo 540 PLAN RHS LHS B A C D E FRONT A B C D E 201 103 570 395 148...

Page 8: ...8 DIMENSIONS Magiglo 750 PLAN RHS LHS B A C D E FRONT A B C D E 201 102 783 606 148...

Page 9: ...9 DIMENSIONS Magiglo 1000 0 PLAN RHS LHS B A C D E FRONT A B C D E 201 103 1029 692 148 Magiglo 540 Double Vision Burner PLAN RHS LHS FRONT D C B A E A B C D E 283 225 540 403 148...

Page 10: ...iving area to spillage of combusted products The flue or chimney should be tested and proven to have an adequate updraught sufficient to remove all waste products of combustion Refer to Commissioning...

Page 11: ...se to the pilot position 2 Keep knob depressed and turn the knob anticlockwise toward the until you hear a click If the pilot lights continue to depress knob for 20 seconds and release If pilot goes o...

Page 12: ...n to the off position 12 LIGHTING INSTRUCTIONS Millivolt Option 1 STOP Read the safety information 2 Push in gas control knob and turn to PILOT 3 NOTE Control knob cannot be turned from OFF to PILOT u...

Page 13: ...they continue to function satisfactorily as multiple flues can work against one another If spillage is detected during this procedure it could indicate a faulty flue or lack or ventilation If the prob...

Page 14: ...products come into the room Smoke match spillage test 225mm DIA GAS COWL Minimum fireplace depth shall be 450mm for all models Maximum fireplace opening height for all models except 1000 shall be 600m...

Page 15: ...AP COAL PLACEMENT IMPORTANT ALL AIR GAPS ON THE UNDERSIDE OF THE BASE GRATE MUST BE SEALED Place base layer of coals as above and randomly stack remainder allowing for gaps Place Air Tubes 5mm behind...

Page 16: ...HIMNEY FOR INSTALLATION OF FIRE BOX REFER TO MANUFACTURER S SPECIFICATIONS This is a guide only Installation of Fire Box must be carried out to manufacturers specifications ATTENTION Existing Chimney...

Page 17: ...to be followed by the engineer can be found under Service Instructions contained within this leaflet 4 For safe operation of your Magiglo the following annual checks should be carried out Confirm that...

Page 18: ...djust burner aeration caps to fully open ULPG setting Tighten screws after adjusting 14 Remove gas pipe from injector 15 Remove injector and replace with correct size 16 Refit injector and retighten g...

Page 19: ...5 03N S I T ODS Pilot Assembly Natural Gas 03P S I T ODS Pilot Assembly Propane Gas 04 1 2 Male to 1 2 Copper Union 05 1 2 to 3 8 Hex Nipple 06 5 16 90O Union Elbow 07 1 4 Nut and Olive 08 Injector Ho...

Page 20: ...elong hotmail com au Sydney NSW Showroom 546 Pacific Highway Chatswood NSW 2067 Ph 02 8905 0189 Fax 02 8905 0192 E mail info realflame com au Miranda NSW Showroom 36 Kareena Rd Miranda NSW 2228 Ph 02...