12
the charger by sliding the battery up to
unlock it from the charger. (Fig 13)
3. Timely recharging of the battery will help prolong the
battery’s life. You must recharge the battery pack when
you notice a drop in the equipment’s power.
IMPORTANT!
Never allow the battery pack to became
fully discharged as this will cause irreversible damage to the
battery.
Charging a Hot or Cold Battery Pack
A red and green flashing indicator light on the charger
indicates that the battery pack temperature is outside the
charging range. Once the pack is within the acceptable
range,normal charging will take place and the red light will
be continuous. Hot or cold battery packs may take longer to
charge.
Operation
IMPORTANT!
This pressure washer is equipped with
a micro-switch sensitive to water flow. This Total Stop
System (TSS) senses water flow in the pump.When the
trigger is released, water stops flowing through the pump .
The TSS then automatically turns the motor off to protect the
pump from overheating,thus saving energy and prolonging
pump life.
The TSS system will work only when there’s water in the
bucket or the base unit is connected with a water supply.
When there’s no water connected with the unit, the On/Off
button has to be pressed to stop the unit.
IMPORTANT!
This system is capable of producing
8Mpa. To avoid rupture and injury, do not operate this pump
with components rated less than 8Mpa working pressure
(including but not limited to spray guns, hose, and hose
connections).
1.Open the battery compartment cover and slide the
battery in until it click to lock it into position, then close the battery
compartment cover (Fig 14).
1.Remove the water bucket from the base unit and fill
with clean (fresh)water . (Fig 15)
WARNING!
The intake water temperature
must not exceed 104
°
F/40
°
C .
CAUTION!
The washer must only be used
with clean (fresh) water; use of unfiltered water
containing corrosive chemicals will damage the water.
WARNING!
Do not fill the bucket with the
bucket still fixed on the base unit.
i. Put the bucket back on the base unit. Make sure
the bucket is properly aligned on the base. Latch and
lock the bucket to ensure the bucket is securely
connected before using.(Fig. 3-4).
Lithium-Ion Charging Status
Battery Pack
Temperature
Red Charger
Indicator Light
Charging
Status
Too hot
Flashing
Not charging
Normal range
Continuous
Normal charging
Too cold
Flashing
Not charging
Summary of Contents for BY-PW02-B2Z-060-02