RDT Informant Installation And User Instructions Manual Download Page 3

3

Connections

Ground

5

F

N

Q

F

S

B

U

V

S

F

Power 4vdc

Sensor 4

Sensor 3

Sensor 2

Sensor 1

Ground

$

P

O

U

B

D

U

Input One

Input Two

Input Three

)

V

N

J

E

J

U

Z

"

N

Q

T

Ground

0 - 5vdc

Contact 1A

Contact 1B

Contact 2A

$

P

O

U

S

P

M

RDTConnections(12-14-11)

Temperature Sensor

Two wires

Combination Temperature & 

Humidity Sensor

Three wires

10 

11

12 

15 

16 

Up to four inputs or 
any  type sensor

1

2

Current 
Transducer

17 

Contact 2B

18 

24vac

Sensor Inputs

Power 

Dry Contact Inputs

Interior Lights

Door 
Position

Leak 

Detector

Ammeter Input

Relay Outputs

Panic Button

To External Alarm

13 

14 

Contact 3A

Contact 3B

Auxiliary Relay

Antenna

M

Coaxial Cable

15 

19

20 

24vac Transformer

Facing the Connector Block (Connector #1 is lowest in control box)

1     2    3     4     5    6    7     8    9   10  11  12   13 14   15  16  17  18  19  20 

Reset 

Button

Summary of Contents for Informant

Page 1: ...____________ 3 Your password is ____________________ Alarms SMS Text Messages Logging to Cloud Server A Temp 8F No alarms Accessing Your Stored Web Data Temperature Refrigerant Leak City Power Amps Hu...

Page 2: ...10 Setting Contact On Off Alarms and Delay 11 Using Delays 11 Setting Temperature Alarm Limits and Delay 12 Set Password 13 Set Celsius or Fahrenheit 13 Sending Test Messages 13 Go To SubMenu Functio...

Page 3: ...ure Humidity Sensor Three wires 7 8 9 10 11 12 15 16 Up to four inputs or any type sensor 1 2 Current Transducer 17 Contact 2B 18 24vac Sensor Inputs Power Dry Contact Inputs Interior Lights Door Posi...

Page 4: ...ponses to menu changes Display Alarm Horn Keypad 1BOJD VUUPO 3FTFU Temperature Sensor Two wire observe polarity Use 22awg stranded wire Up to four can be used Has 24 leads Combo Temperature and Humidi...

Page 5: ...t Lighting Relay Output Ext Horn Relay Output Aux Relay Lighting Horn Refrigerant Leak Detector Panic Button 9vdc Transformer Door Switch Alarm Horn Panic Reset Informant Power Leak Detector Power Inf...

Page 6: ...magnetic switch automatically controls the internal lighting Once the door is opened an internal timer in the Informant starts running If the door is closed promptly the lights are shut off If the do...

Page 7: ...larm Manual scrolling by pressing the B and C keys Scrolling Menu on Internal Display Top Menu 85F Signal Strength Indicator Unusable Signal Strength Marginal but usable Excellent signal level This de...

Page 8: ...re than five miles from the cell phone tower a directional antenna will likely be required Typical directional antenna Yagi Usually mounted outside building Typical non directional tenna monopole Ante...

Page 9: ...degC 9 Send Test Text Message 0 More options zero key 0 Press 0 Key To Access Sub Menu Sub Menu Functions 1 City Power Alarm 2 Battery Low Alarm 3 Contact 1 Alarm 4 Contact2 Alarm 5 UDP Logging 6 SMS...

Page 10: ...ration Set Contacts 1 and 2 Delay Time Contact1 dly 0 1 Change The value is minutes until an alarm is activated These devices frequently monitor refrigerator doors and alarm if the door is left open f...

Page 11: ...enu function enables the contacts operation Adjusting Delay Time minutes Contact1 dly 0 Setting Contact On Off Alarms and Delay The on off contact sensing is set up in the sub menu See page 13 for mor...

Page 12: ...elay Before Alarm 1 Temp 1 Delay Shortcut Press A and scroll down to 5 120 Setting Negative Temperature Values Enter Hi Alarm 1 Press D for Done Shortcut Press A and 6 0 for no delay Enter minutes Set...

Page 13: ...ech support to have an upload of the firmware done There is no back door method Set Password Set Password Set Celsius or Fahrenheit 2 Celsius 1 Fahrenheit Select the temperature portrayal of F or C Al...

Page 14: ...f 1 Enable When the device cannot receive ity ower it reverts to long live batteries CR123 Lithium If ity ower remains off for longer than 20 hours the unit will send an alarm that it will soon be com...

Page 15: ...ated These devices frequently monitor refrigerator doors and alarm if the door is left open for a long time If set to zero there is no delay A submenu function enables the con tacts operation Off 1 En...

Page 16: ...ilent Mode Silent Mode Off 1 Enable Use this mode to block accidental setting of passwords in the Main Menu The default password to enable the keypad is 1 Keypad Lock Keypad lock Off 1 Enable Turns of...

Page 17: ...ice to return to the scrolling menu Set tem limits for alarm functions Up to four temperature sensors can be used Each sensor has a unique internal address and must be discovered by the unit in order...

Page 18: ...ds on the server can be customized No special software is required Steps to accessing your Informant s stored data 1 Open a Internet browser connection using Explorer Chrome Firefox 2 Type http app co...

Page 19: ...19 Typical Report HTML format Graph and Report Generator Sub Menu Report formats Graphs Excel HTML browser text Spreadsheet CSV...

Reviews: