[5] RJ45 Connectors for Power Battery and Power Sensor
The inverter communicates with the battery via the CAN-Bus.
If inverter is delivered with optional Power Sensor and Power Switch please refer to user manual of these items for
further detailed commissioning information.
Fig. 4
RJ45
– Communication Ports
[5.1] Connection of RJ45
– Communication Ports
[5.2] Wiring of RJ45
– Communication Ports
Communication with Power Battery
Additional Power Sensor Communication
Item Description
A
CAN BUS:
Battery communication connector.
B
Power Sensor:
Power Sensor communication connector.
Step
Description
1
Open cable entry (Fig. 1, c) and feed cables.
2
Select correct port (see Fig. 4 and next section), insert cables in RJ45 connectors.