INFO Menu
The INFO menu displays information about the thermostat. Use the Up/Dn buttons to scroll
through the various items.
Thermostat information displayed:
VERSION
Thermostat firmware version
ZWAVE
Z-Wave firmware version
NODE ID
Z-Wave Node ID
HOME ID
Z-Wave Home ID
SYSTEM TYPE
displays current System Type setting (Standard or Heat Pump)
If System Type = Standard
FAN TYPE
displays current Fan Type setting
If System Type =
Heat Pump
CHANGEOVER TYPE
displays current Change Over valve (reversing valve) setting
Thermostat Operation
Minimum Run Time (MRT)
The thermostat has a Minimum Run Time (MRT) delay after the start of any heating or
cooling call. This minimum run time assures even heating and cooling cycles. The MRT
will keep the system on, even if it reaches the setpoint room temperature, or you change
the setpoint to a temperature that would satisfy the call, until the MRT expires. Changing
the Mode to OFF will cancel the MRT and the system will turn off immediately. The MRT
can be adjusted in the Advanced Settings menu of the thermostat.
Note: The MRT status is shown in the thermostat Status display
.
Minimum Off Time (MOT)
The thermostat has a Minimum Off Time (MOT) delay after any heating or cooling cycle
ends. This delay prevents rapid heating/cooling cycles and also provides “short cycle
protection” for the system compressor. This delay may be noticeable when you change a
setpoint and it does not respond immediately due to the MOT delay timer preventing the
system from restarting. The MOT delay time can be adjusted in the Advanced Settings
menu of the thermostat but there is a minimum of 5 minutes delay to assure compressor
protection.
Note: The MOT status is shown in the thermostat Status display.