OPERATING ELEMENTS / CONNECTIONS

 BAN-120/240

FRONT PANEL

1.  Level indication

 for the power amplifier in case of over-

load, the red LED CLIP will light up

2.  Volume control 

for the signal at the input PGM INPUT 

(11) 

3.   Status LEDs

 

 

FAULT will light up if a fault has occurred in the amplifier 

 

PROTECT will light up if the amplifier is overheated or a 
fault has occurred in the amplifier 

 

PRIORITY will light up if the amplifier is switched over to 
the PRIORITY INPUT (16) via the terminal PRI CTL (14) 

 

POWER power LED 

4.  POWER switch  

 

Note: If a 24 V voltage from an emergency power supply 
unit is applied to the terminal DC POWER (6), it will not be 
possible to switch off the amplifier.

FRONTANSICHT

1.   Pegelanzeige

 für die Endstufe bei Übersteuerung leuchtet 

die rote LED CLIP 

2.   Lautstärkeregler

 für das Signal am Eingang PGM INPUT 

(11) 

3.   Status-LEDs

 

 

FAULT leuchtet, wenn ein Fehler im Verstärker aufgetreten 
ist 

 

PROTECT  leuchtet,  wenn  der  Verstärker  überhitzt  oder 
ein Fehler im Verstärker aufgetreten ist 

 

PRIORITY  leuchtet,  wenn  der  Verstärker  über  den  An-
schluss PRI CTL (14) auf den Eingang PRIORITY INPUT 
(16) umgeschaltet ist 

 

POWER Betriebsanzeige 

4.   Ein-/Ausschalter POWER  

 

Hinweis: Liegt eine 24-V-Spannung von einer Notstrom-
einheit am Anschluss DC POWER (6) an, lässt sich der 
Verstärker nicht ausschalten. 

RüCKANSICHT

Hinweis: Alle grünen Anschlussleisten lassen sich zu besseren 
Handhabung beim Festschrauben der Anschlussleitungen von 
ihren Steckverbindungen abziehen.

5. 

Netzbuchse zum Anschluss an eine Steckdose (230V/50Hz) 
über das beiliegende Netzkabel 

6.

   Anschlüsse DC POWER für eine 24-V-Notstromeinheit 

7.

   Abdeckblech,  wird  beim  Einsetzen  des  Fehlerüberwa-

chungsmoduls FM-30 entfernt 

8.

   Die Relaiskontakte schalten um, wenn der Verstärker über 

den Anschluss PRI CTL (14) auf den Eingang PRIORITY 
INPUT (16) umgeschaltet wird 

9.

   Lautsprecheranschlüsse 

10.

  Abdeckblech,  wird  beim  Einsetzen  des  Fehlerüberwa-

chungsmoduls FD-20 entfernt 

REAR PANEL

Note: To facilitate handling when screwing on the connection 
cables,  all  green  terminal  strips  can  be  disconnected  from 
their plug-in connections. 

5. 

Mains jack for connection to a socket (230V/50Hz) via the 
mains cable supplied 

6. 

Terminals DC POWER for a 24 V emergency power supply 

7.

  Cover plate, to be removed when inserting the fault de-

tection module FM-30

8.

   The relay contacts will switch over if the amplifier is swit-

ched over to the PRIORITY INPUT (16) via the terminal 
PRI CTL (14) 

9.

  Speaker terminals 

10.

 Cover plate, to be removed when inserting the fault de-

tection module FD-20 

G

SPEAKER

OUTPUT

C

O

M

2

5

V

50

V

10

0

V

PGM

INPUT

OUT

PRI

CTL

GND

+24 V

G

SPEAKER

OUTPUT

C

O

M

2

5

V

50

V

10

0

V

PGM

INPUT

OUT

PRI

CTL

GND

+24 V

AMP 1

G

PRIORITY

INPUT

G

PRIORITY

INPUT

AMP 2

PGM

INPUT

PRIORITY

INPUT

. . . . . . .

max.

240W

RMS

PRIORITY

CONTROL

1

2

3

4

OUTPUT LEVEL

LEVEL

STATUS

FAULT

PROTECT

PRIORITY

POWER

0

10

CLIP

0

-3

-8

-13

BAN-120

  NATURAL COOLING P.A. AMPLIFIER

POWER

G

230 V~/50 Hz

DC POWER

24 V

4

/10A

PRIORITY

RELAY

CONTACT

MAX 3 A

SPEAKER

OUTPUT

C

O

M

2

5

V

5

0

V

10

0

V

C

O

M

5

.2

20

.8

83

.3

PGM

INPUT

0 dBu (0.775 V)

60 kΩ BAL

OFF

ON

400 Hz

FD-20

NORMAL

PILOT TONE

ON: NORMAL

OFF: FAULT

MAX 0.5 A

G

0 dBu (0.775 V)

60 kΩ BAL

PRIORITY

INPUT

LEVEL

SLAVE

INPUT

100 V

0

0

10

OUT

PRI

CTL

GND

+24 V

5

6

7

8

9

10

11

12 13

14 15

16 17

Fault Detector

COM HOT

Line In

Test

RMS 2Vac

Sensitivity

max

min

OSC Level

FD-20

18 19 20 21 22

23

SW1

ON  OFF

CN601

G

SPEAKER

OUTPUT

C

O

M

25

V

5

0

V

10

0

V

PGM

INPUT

OUT

PRI

CTL

GND

+24 V

G

SPEAKER

OUTPUT

C

O

M

25

V

5

0

V

10

0

V

PGM

INPUT

OUT

PRI

CTL

GND

+24 V

G

SPEAKER

OUTPUT

C

O

M

25

V

5

0

V

10

0

V

PGM

INPUT

OUT

PRI

CTL

GND

+24 V

G

SPEAKER

OUTPUT

C

O

M

25

V

5

0

V

10

0

V

PGM

INPUT

G

PRIORITY

INPUT

OUT

PRI

CTL

GND

+24 V

AMP 1

G

PRIORITY

INPUT

G

PRIORITY

INPUT

G

PRIORITY

INPUT

AMP 2

AMP 3

AMP 4

PGM

INPUT

PRIORITY

INPUT

. . . . . . .

max.

480W

RMS

PRIORITY

CONTROL

AC

DC

FAN

FM-30

  FAULT MONITOR MODULE

24

25

Summary of Contents for BAN-120

Page 1: ...OPERATING INSTRUCTIONS BEDIENUNGSANLEITUNG BAN 120 240 NATURAL COOLING AMPLIFIER ENGLISH DEUTSCH 120 W 240 W fanless cooling...

Page 2: ...service contact your dealer Wichtige SICHERHEITSHINWEISE Bitte lesen Sie die Sicherheitsanweisungen bevor Sie das Ger t in Betrieb nehmen 1 Installation nach folgenden Richtlinien Stellen Sie das Ger...

Page 3: ...tANSICHT 4 BAN 120 240 REAR VIEW R CKANSICHT 5 FD 20 PILOTTONE MODULE PILOTTON MODUL 6 FM 30 ERROR MONITORING MODULE FEHLER MELDE MODUL 7 BAN 120 240 CONNECTING THE AMPLIFIER VERST RKER ANSCHLIESSEN 8...

Page 4: ...auf den Eingang PRIORITY INPUT 16 umgeschaltet wird 9 Lautsprecheranschl sse 10 Abdeckblech wird beim Einsetzen des Fehler berwa chungsmoduls FD 20 entfernt Rear Panel Note To facilitate handling when...

Page 5: ...st Nr 3 zum Ein und Ausschalten des 20 kHz Testtons wenn das Modul FD 20 eingebaut ist 13 Kontroll LED leuchtet wenn der Verst rker ordnungsge m arbeitet 14 Anschl sse OUT f r den 24 V Ausgang Spannun...

Page 6: ...Lautsprecherleitung indem es ein 20 kHz Sinussignal mit einer Spannung von 2 V bei 70 or 100 V Linie ausgibt Anschl sse zum Anschluss von Signalgebern 18 Relaisausgang zum Anschluss eines Signalgeber...

Page 7: ...evices 23 Relay outputs to connect signal devices Relay AC will re spond if no mains voltage is applied if the internal mains fuse has blown or if the unit has been switched off with the POWER switch...

Page 8: ...erst rker einstellen von dem das 100 V Signal auf den BAN 120 gegeben wird Vorrangrelais und 24 V Ausgang Sobald ein mit den Klemmen PRI CTL 14 verbundener Vor rangschalter oder verbundenes Relais ges...

Page 9: ...romver sorgung umgeschaltet 2 Zum Schluss das beiliegende Netzkabel zuerst in die Netzbuchse 5 und dann in eine Steckdose 230V 50Hz stecken switch over Its terminals PRIORITY RELAY 8 allow to con trol...

Page 10: ...das Fehler berwachungsmodul FD 20 Abb 3 nicht eingesetzt den DIP Schalter Nr 2 12 auf der Verst rker r ckseite in die untere Position ON stellen sonst spricht die Schutzschaltung an Operation 1 To pre...

Page 11: ...IO Eingangsempfindlichkeit Impedanz PGM Power Consumption BAN 120 335 W Leistungsaufnahme BAN 240 735 W Speaker Output Ausg nge Lautsprecher 25 V 50 V 100 V Input Filter Eingangsfilter 400 Hz 3 dB HPF...

Page 12: ...ct permission Ver ffentlichung und Vervielf ltigung der enthaltenen Daten auch auszugsweise nur mit unserer ausdr cklichen Genehmigung RCS19 10 2009 Hardware and Software specifications subject to cha...

Reviews: