background image

READ INSTRUCTIONS CAREFULLY BEFORE USING 

THIS PRODUCT. SAVE INSTRUCTIONS FOR 

LATER REFERENCE.

PRODUCT IS NOT SUITABLE FOR PHASE DIMMING

Products must be installed by a suitably qualified 

professional only. Installations must conform to national 

installation codes and accident prevention regulations.

If using a track adaptor, ensure it is compatible with the 

track system installed. Failure to do so may result in 

danger of electric shock and damage to the product. 

Ensure electrical rating shown on product label 

conforms to mains voltage supply.

Do not modify the product in any way. RCL accepts 

no  responsibility for damage caused by modifying 

this product.

Product is rated IP20 unless otherwise stated. Install 

indoors only and away from damp or wet environments.

This symbol indicates the minimum distance to a 

lighted object and must be observed.

Caution, product will become hot in use. Allow to cool 

before touching.

Dispose of this product in accordance with WEEE or 

other national regulations.

Products marked with this symbol are compliant with 

Class 2 regulations.

If you have any difficulty installing this product 

please contact:

Remote Controlled Lighting Ltd (UK)

42 Riverside Road, London SW17 0BA

+44 (0) 20 8404 2400

[email protected]

Remote Controlled Lighting Ltd (Asia)

Unit 13, 8/F, Lai Sun Yuen Long Centre

21-35 Wang Yip Street East, 

Yuen Long, Hong Kong

+852 2310 9733

Installation Instructions

Remote Controlled Spotlight Type DR8 Mk2

Important Safety Information

DOC-260-A

Copyright © 2016 Remote Controlled Lighting Ltd. All Rights Reserved.

BEFORE YOU START

Read these instructions carefully. For the latest 

instructions on all our products see 

www.rclighting.com/downloads

These instructions cover the following 

installation methods:

3-Circuit Installation

2-Circuit Installation

1-Circuit Installation

Monopoint Installation

Trough Installation

Lamp Change - QR111

Lamp Change - HIR111-CE-P

Lamp Change - HIT-CE

Accessory Change

Snoot Installation

A

B

C

D

E

F

G

H

I

J

1

2

3

4

5

6

Ensure that the track system where the DR8 luminaire 

is to be installed is compatible with the Eutrac 

3-Circuit adaptor.

A

3-Circuit Track Installation

If the spotlight is to be controlled via  DMX or DALI, 

ensure that track system includes Data Bus. See For 

more information on DMX Installation see DOC-083.

NOTES

2
3

1

N

*note orientation

Insert the track adaptor into track system. Take  care 

to  avoid any fixing screws holding the track onto the 

ceiling.

To mount the track adaptor into the track system, first 

check that both the selector knob       and the adaptor 

lock      are disengaged, as shown below.

Rotate selector knob      to the desired circuit position 

(see section 7).

Rotate adaptor lock        clockwise 90° to connect the 

adaptor to the neutral circuit.

When installing the adaptor into the track, ensure that 

it is orientated correctly. Align the tabs      with the 

slot      on the track.

PAGE 1

Summary of Contents for DR8 Mk2

Page 1: ...ip Street East Yuen Long Hong Kong 852 2310 9733 Installation Instructions Remote Controlled Spotlight Type DR8 Mk2 Important Safety Information DOC 260 A Copyright 2016 Remote Controlled Lighting Ltd All Rights Reserved BEFORE YOU START Read these instructions carefully For the latest instructions on all our products see www rclighting com downloads These instructions cover the following installa...

Page 2: ... Bus See For more information on DMX Installation see DOC 083 NOTES 2 1 N note orientation PAGE 3 2 To mount the track adaptor into the track system first check that both the selector knob and the adaptor lock are disengaged as shown below 3 4 5 6 Insert the track adaptor into track system Take care to avoid any fixing screws holding the track onto the ceiling Rotate selector knob to the desired c...

Page 3: ... it is orientated correctly Align the tabs with the slot on the track 1 DMonopoint Installation The monopoint fixture requires a minimum clearance distance of 200mm above and around the mounting point and a maximum ceiling material thickness of 50mm 200mm MIN 200mm MIN 50mm MAX 2 3 Mark up the ceiling and cut a circular hole 112 114mm in diameter For multiple installations ensure a minimum distanc...

Page 4: ...es will align Ensure that the monopoint head studs locate securely in the mounting ring hooks as shown below 9 10 8 7 4 5 6 Insert the mounting ring into the hole so that it sits flush with the ceiling Holding the mounting ring in place insert a fixing clip into a slot on the mounting ring Slide the fixing clip down the slot until it hits the ceiling material Ensure that the luminaire is securely ...

Page 5: ...ack 220mm MIN Monopoint When mounting luminaires in troughs always observe the minimum distance to a lighted object as indicated on the fixture For more information regarding correct trough installation please contact RCL directly IMPORTANT 1 2 3 1 3 4 1 2 GLamp Change HIR111 CE P HLamp Change HIT CE I Accessory Change Avoid contact with skin when handling HIT CE lamps Wear gloves where possible I...

Page 6: ...cessory holder and reverse the process to reassemble the bezel and reattach to the DR8 spotlight Safety Glass Slot 2 Slot 1 The accessory holder can hold up to two lenses depending on the lamp type not LED Slot 1 Slot 2 Extended Snoot NOTE ORIENTATION Insert the snoot into bottom slot of the accessory ring as shown and bring the two halves of the ring together Insert the bezel ring over the snoot ...