PAGE 8
1
2
3
1
2
E
Trough Installation
F
Lamp Change - QR111
The track system or monopoints should be mounted
centrally within the trough.
NOTES
If installing the DR8 luminaire into a trough, ensure a
minimum internal trough width of 220mm.
To prevent overheating, troughs must be suitably
ventilated. Holes or slots with a minimum area of
600mm2 should be included at 500mm intervals
along the trough length.
600mm2
500mm MAX.
Unclip accessory holder and dispose of lamp
correctly. To install a new lamp, reverse this process
making certain lamp connectors are secured tightly to
ensure a good connection and to avoid damage.
Disconnect product from mains voltage supply and
allow to cool before replacing lamp.
Twist DR8 bezel anti-clockwise and remove from
luminaire.
Unscrew lamp screws and disconnect the lamp
connectors from the lamp.
220mm MIN.
Track
220mm MIN.
Monopoint
When mounting luminaires in troughs, always
observe the minimum distance to a lighted object, as
indicated on the fixture.
For more information regarding correct trough
installation, please contact RCL directly.
IMPORTANT
1
2
3
1
3
4
1
2
G
Lamp Change - HIR111-CE-P
H
Lamp Change - HIT-CE
I
Accessory Change
Avoid contact with skin when handling HIT-CE
lamps. Wear gloves where possible.
IMPORTANT
Unclip accessory holder and dispose of lamp
correctly. To install a new lamp, reverse this process
ensuring lamp is secured tightly.
Disconnect product from mains voltage supply and
allow to cool before replacing lamp.
Twist DR8 bezel anti-clockwise and remove from
luminaire.
Disconnect product from mains voltage supply and
allow to cool before replacing lamp.
Twist DR8 bezel anti-clockwise and remove from
luminaire.
Twist DR8 bezel anti-clockwise and remove from
luminaire. If necessary, disconnect the lamp.
Twist the lamp anti-clockwise to disconnect.
Remove the lamp from it’s socket. To install a new
lamp, reverse this process.
PAGE 9