RCI 9325 Quick Start Manual Download Page 2

6

5

4

9

8

7

3

2

1

0

*

6

5

4

9

8

7

3

2

1

0

*

x1

x1

x6

x2

x2

x2

x2

x1

x1

x1

Fig. 6  Marking Out Mounting Position. The supplied bracket
allows easy marking out before drilling and mounting the
keypad. Drill the cable clearance hole in the center of the
rectangular aperture. (All screws and wall plugs are supplied.)
You will need a No.2 Philips head screwdriver, a drill and a
pencil

.

Fig. 3 Items Supplied with 9325i. If any items are 
missing or damaged, please contact your vendor.

Fig. 5 Assembling the 9325i Keypad. The cable should be
connected as described in the instructions on page 1. A
choice of silicone seal is provided depending on the
diameter of the cable used. The cable clamp is screwed
down to hold the cable firmly at the back of the keypad.

©2010 RUTHERFORD CONTROLS INT’L CORP. WWW.RUTHERFORDCONTROLS.COM

USA: 2697 INTERNATIONAL PARKWAY, PKWY 5, VIRGINIA BEACH, VA 23452 • CANADA: 210 SHEARSON CRESCENT, CAMBRIDGE, ON  N1T 1J6 

PHONE • 1.800.265.6630 • 519.621.7651 • FAX: 1.800.482.9795 • 519.621.7939 • E-MAIL: [email protected]

9325 Keypad Installation Instructions 

(Continued)

6

5

4

9

8

7

3

2

1

0

*

x1

x1

x2

x1

x2

x1

Fig. 4 Items Supplied with 9325e. If any items are 
missing or damaged, please contact your vendor.

9325i Interior Keypad

9325e Weatherproof or Exterior Keypad

9325e is a sealed unit
and cannot be opened.

2

Silicone Seal

Rear view of
keypad

Step 1

Step 2

Step 3

Summary of Contents for 9325

Page 1: ...l keypad settings The first time the keypad is turned on the green and red LEDs will flash alternately Choose a 6 digit number and make a note of it here This will be the new master code Press followed by the new master code then Press and re enter the new master code then Press to confirm the code and finish Now that the master code is defined type 7890 on the keypad The door should open Note The...

Page 2: ...ice of silicone seal is provided depending on the diameter of the cable used The cable clamp is screwed down to hold the cable firmly at the back of the keypad 2010 RUTHERFORD CONTROLS INT L CORP WWW RUTHERFORDCONTROLS COM USA 2697 INTERNATIONAL PARKWAY PKWY 5 VIRGINIA BEACH VA 23452 CANADA 210 SHEARSON CRESCENT CAMBRIDGE ON N1T 1J6 PHONE 1 800 265 6630 519 621 7651 FAX 1 800 482 9795 519 621 7939...

Page 3: ...er new 6 digit code re enter code Exit button operation Normal Toggle Disabled User codes enter user code 4 8 digits re enter code press to confirm code as normal code press to confirm code as a toggle code press to delete this user code 1 2 3 Data reset Re enter the master code Press and hold for 3 Seconds 9 This returns all the settings except multi user to the factory defaults with a single use...

Page 4: ...cceptable level For additional security set the lockout option to block the keypad after 20 incorrect keystrokes Remember to delete the factory default user code 7890 after entering multi user codes How to set up the keypad to work with a fail unlocked release A fail unlock release is used where it is necessary for the door to become unlocked in the case of power failure This is typically done whe...

Page 5: ... open when I enter my code Check that there is power to the keypad by pressing the keys and listening for keypad beeps If no beeps are heard check the power supply Check that the green light flashes when the correct code is entered If not the code has not been entered correctly or may have been incorrectly programmed Check that the lock is capable of operating with a 12VDC power supply Check conne...

Page 6: ...changing the output Model number 9325i is preset at factory default with output configured as SPST N O relay By changing the jumpers on the back of the keypad as shown the output terminals can be reconfigured to supply 12VDC power directly to the locking device Note Polarity must be observed Important Remove power to keypad before changing jumper settings Failure to remove power may cause damage t...

Page 7: ...SON CRESCENT CAMBRIDGE ON N1T 1J6 PHONE 1 800 265 6630 519 621 7651 FAX 1 800 482 9795 519 621 7939 E MAIL SALES RUTHERFORDCONTROLS COM 9325 Keypad Installation Instructions Continued N O Pushbutton If Required White Wire Black White Wire Black Wire White Wire Gray Wires 12VDC Power Supply 1 4 7 2 3 5 6 8 9 0 Fig 10 Typical wiring of an electromagnetic lock through the interior 9325i relay Fig 11 ...

Page 8: ...A 1 2A 3 4A 1A 1 1 4A 1 1 2A 2A 3A 100 24 20 18 18 16 16 14 12 150 22 18 16 16 14 14 12 10 200 20 18 16 14 14 12 12 10 250 18 16 14 14 12 12 12 10 300 18 16 14 12 12 12 10 400 18 14 12 12 10 10 500 16 14 12 10 10 750 14 12 10 10 1000 14 10 10 1500 12 10 Total One Way Length of Wire Run ft Load Current 12V 1 4A 1 2A 3 4A 1A 1 1 4A 1 1 2A 2A 3A 100 20 18 16 14 14 12 12 10 150 18 16 14 12 12 12 10 20...

Reviews: