RCF P3108 User Manual Download Page 10

10

ENGLISH

IMPORTANT 

NOTES

Before connecting and using this product, please read this instruction manual carefully and keep 
it on hand for future reference. This manual is to be considered an integral part of this product and 
must accompany it when it changes ownership as a reference for correct installation and use as well 
as for the safety precautions.
RCF  S.p.A.  will  not  assume  any  responsibility  for  the  incorrect  installation  and  /  or  use  of  this 
product.

WARNING: 

To prevent the risk of fire or electric shock, never expose this loudspeaker to rain 

or humidity and dust, but the case this has been adapted as a sealed box with IP 55 protection 

grade.

SAFETY PRECAUTIONS

1. 

All the precautions, in particular the safety ones, must be read with special attention, as they 
provide important information.

2.

  Loudspeaker lines (amplifier outputs) can have a sufficiently high voltage to involve a risk of 

electrocution: never install or connect this loudspeaker when amplifiers are switched on.

3.

  Make sure all connections have been made correctly and the loudspeaker input voltage (in a 

constant voltage system) or its impedance is suitable for the amplifier output.

4. 

Protect loudspeaker lines from damage; make sure they are positioned in a way that they cannot 
be stepped on or crushed by objects.

5. 

Make sure that no objects or liquids can get into this product, as this may cause a short circuit.

6.

  Never  attempt  to  carry  out  any  operations,  modifications  or  repairs  that  are  not  expressly 

described in this manual. 

 

Contact  your  authorized  service  centre  or  qualified  personnel  should  any  of  the  following 
occur:

The loudspeaker does not function (or works in an anomalous way).
The cable has been damaged.
Objects or liquids are inside the loudspeaker.
The loudspeaker has been damaged due to heavy impacts or fire.

7. 

Should the loudspeaker emit any strange odours or smoke, remove it from the line after having 
immediately switched the amplifier off.

8.

  Do not connect this product to any equipment or accessories not foreseen.

 

For suspended installation, only use the dedicated anchoring points and do not try to hang this 
loudspeaker by using elements that are unsuitable or not specific for this purpose.

 

Also check the suitability of the support surface to which the product is anchored (wall, ceiling, 
structure, etc.), and the components used for attachment (screw anchors, screws, brackets not 
supplied by RCF etc.), which must guarantee the security of the system / installation over time, 
also considering, for example, the mechanical vibrations normally generated by transducers.

9.  RCF S.p.A.

 strongly recommends this product is only installed by professional qualified installers 

(or  specialised  firms)  who  can  ensure  a  correct  installation  and  certify  it  according  to  the 
regulations in force.

 

The  entire  audio  system  must  comply  with  the  current  standards  and  regulations  regarding 
electrical systems.




Summary of Contents for P3108

Page 1: ...the rules of sound P3108 User manual Manuale d uso P SERIES LOUDSPEAKER DIFFUSORE ACUSTICO SERIE P...

Page 2: ......

Page 3: ...A CLUSTER pag 07 COLLEGAMENTO pag 07 NOTE SUI SISTEMI CON CONNESSIONE A BASSA IMPEDENZA pag 08 DATI TECNICI pag 09 INDEX SAFETY PRECAUTIONS page 10 DESCRIPTION page 12 SEALED OR VENTED BASS REFLEX BOX...

Page 4: ...iata da oggetti al fine di salvaguardarne la perfetta integrit 5 Impedire che oggetti o liquidi entrino all interno del prodotto perch potrebbero causare un corto circuito 6 Non eseguire sul prodotto...

Page 5: ...usore acustico in grado di produrre 12 I diffusori devono essere collegati in fase corrispondenza delle polarit tra amplificatori e diffusori in modo da garantire una corretta riproduzione audio sopra...

Page 6: ...te un connettore a tenuta stagna Include un driver per le alte frequenze al neodimio RCF Precision da 1 membrana da 1 5 caricato a tromba con direttivit costante ed un woofer da 8 bobina da 2 5 per le...

Page 7: ...alizzato in conformit con le norme e le leggi vigenti in materia di impianti elettrici I diffusori devono essere collegati in fase corrispondenza delle polarit tra amplificatori e diffusori in modo da...

Page 8: ...i deve essere ridotta al minimo Impedenza complessiva 4 8 Impedenza complessiva 8 8 8 MAX 2 5 mm2 MAX 2 5 mm2 INGRESSO USCITA PARALLELA 4 3 1 2 Osservando la parte posteriore del connettore E collegar...

Page 9: ...493 x 250 mm Peso 10 kg COMPONENTI WOOFER PER BASSE FREQUENZE Tipo 8 bobina 2 5 Impedenza 8 Potenza AES picco 300 W 1200 W Sensitivit 1 W 1 m 95 dB DRIVER PER ALTE FREQUENZE Tipo tromba 1 membrana 1 5...

Page 10: ...o this product as this may cause a short circuit 6 Never attempt to carry out any operations modifications or repairs that are not expressly described in this manual Contact your authorized service ce...

Page 11: ...ensure a correct sound reproduction loudspeaker phase is to be respected loudspeakers are connected respecting the amplifier polarity This is important when loudspeakers are installed adjacent one an...

Page 12: ...connector The high frequency section has a constant directivity horn with a 1 RCF Precision Neodymium compression driver 1 5 diaphragm The low frequency transducer is a 8 woofer 2 5 voice coil SEALED...

Page 13: ...d and installed in compliance with the current local laws and regulations regarding electrical systems To ensure a correct sound reproduction loudspeaker phase is to be respected loudspeakers are conn...

Page 14: ...as short as possible Total impedance 4 8 Total impedance 8 8 8 MAX 2 5 mm2 MAX 2 5 mm2 INPUT PARALLEL OUT 4 3 1 2 Locking at the rear side of the female contact insert E connect the wire coming from...

Page 15: ...1 8 kHz Dimensions w h d 266 x 493 x 250 mm Weight 10 kg TRANSDUCERS LF DRIVER Type 8 woofer 2 5 coil Impedance 8 Power AES peak 300 W 1200 W Sensitivity 1 W 1 m 95 dB HF DRIVER Type 1 horn loaded 1...

Page 16: ...2 274411 fax 39 0522 274484 e mail rcfservice rcf it Salvo eventuali errori ed omissioni RCF S p A si riserva il diritto di apportare modifiche senza preavviso Except possible errors and omissions RCF...