CONTINUITY TEST CHART—Continued Unscrew Pilot
Lamp Before Making Test
Circuit
Test Terminals
Correct Effect
Incorrect Effect
Indication
Caused By
Filament
—
Fl to Ground
Closed (6.5 Ohms)
,0pen Short
Open UX-222 filament resistor or connection
Shorted .1 mfd. condenser
—P2 to Ground
Closed (6.5 Ohms)
Open
Short
Open UX-222 filament resistor or connection
Shorted .1 mfd. condenser
—F3 to Ground
Closed (Short)
Open
Open connection
—F4 to Ground
Closed (Short)
Open'
/ Open connection
—P5 to Ground
Closed (Short)
Open
Open connection
+F1 to +A (Yellow)
Closed (1.55
Ohms)
Open
Open 1.55 ohm resistor or connection
+F2 to +A (Yellow)
Closed (1.55
Ohms)
Open
Open 1.55 ohm resistor or connection
+F3 to +A (Yellow)
Closed (1.95
Ohms)
Open
Open 1.95 ohm resistor or connection
+F4 to +A (Yellow)
Closed (1.95
Ohms)
Open'
Open 1.95 ohm resistor or connection
+F5 to +A
(Yellow)
Closed
(1.55 Ohms)
Open
Open 1.55 ohm resistor or connection
Misc.
Antenna to ground
(Switch at "distant"
position)
Closed (30 Ohms)
Open
Open connection, antenna loading coil, or
primary of first R.F. transformer
B+67 (Maroon) to
A—(Black with
Yellow tracer) (Close
op. sw.).
Closed (50,000
Ohms)
Open
Open volume control
—Fl to B+13S
(Maroon and Red)
Open
Closed
Shorted .1 mfd. condenser
—F2 to B+ 135
(Maroon and Red)
Open
Closed
Shorted :1 mfd. condenser
B+135 (Maroon and
Red) to ground
Open
Closed
Shorted 1 mfd. condenser
P3 to —F3
Open
Closed
Shorted 1 mfd. condenser or .0012
mfd. condenser
G4 to —F4
Open
Closed ,
Shorted .00016 mfd. condenser
SG1 to —Fl
Open
Closed
Shorted 0.1 mfd. condenser
SG2 to —F2
Open
Closed
Shorted 0.1 mfd. condenser
15