Operation
To operate the door simply press the hand held transmitter or
the control unit switch for two seconds and the door will
automatically open or close. The door can be stopped during
the opening or closing cycle by pressing the control unit switch
or handheld transmitter. The next actuation will move the door
in the opposite direction.
Safety Obstructive Reverse
While the door is in the closing cycle it will automatically reverse
if it hits an obstacle or is restricted in some way. The amount
of pressure the door applies before reversing is adjustable.
Similarly, if restricted whilst opening the door will stop.
Automatic Courtesy Light
The Courtesy Light on the opener comes on automatically
whenever the door is activated to do an opening or closing
cycle. The light will stay on for
approximately three minutes before turning off.
Security Code Store
The opener uses state of the art microchip 1 technology in
storing your Rolling Code Transmitter Security Code. Up to
20 different remote control codes can be stored in the non-
volatile memory device. To store any code simply press the
LEARN button on the opener and press the remote control
button twice. The codes can be deleted at any time. Security
is enhanced because the fixed and encrypted sections
combined increase the number of combinations to 7.38 x
1019. There are no Dip switches on the opener which can be
visually seen and copied.
Open and Close Drive Button
Another feature developed to aid in the installation of the
opener are the 0/S/C Buttons. These buttons are used to help
set the open and close limit positions. The quicker setting time
and a more precise limit position can be achieved using this
system.
Auto Close Mode
The opener can be programmed to automatically close
approximately thirty seconds after the door has opened. A
Photoelectric Beam must be installed if this mode is selected.
Auto Run Time
If the motor is left running in the disengaged mode for any
reason the Auto Run Time will turn the motor off after 30
seconds.
Photo Electric Beam
The opener has an input for a Photo Electric Beam to be
connected for extra safety protection.
Maintenance
No particular maintenance is required for the Motor Control
Unit. However, check at least twice a year that the unit is in
proper working order. Adjust if necessary the motor force.
Make sure that the safety devices are working effectively.
Check once a month that the drive reverses when an object
(40mm or higher) is placed in the door’s path.
If you experience any problems, contact ORCA on
Freephone 0800 ORCAHELP
Features
Your automatic roller door opener has many features which
you will appreciate. The components and materials used in
this control board are of the latest technology and highest
quality. Below are listed some of the features,