Page 1: ...LumenDimM4micro Quick Start Guide Rev 1 0...
Page 2: ...2 2 10 12 RF F CD AB 1 2 3 6 7 8 4 9 5 D C B A IN 11 D C B A IN DimA DimB DimC DimD...
Page 3: ...DCin 1 Connector is Amp MTA 100 Series 0 1 pin spacing Shell color indicates wire gauge Red shell is for 22 AWG wire Amp connector P N 3 641190 6 Numerous alternatives are available each with differen...
Page 4: ...as a wide variety of expanded features for advanced users You can find out more about all of them in the RC4 Knowledge Base at http rc4 info Registering Your Product Registering your LumenDimM4micro i...
Page 5: ...ent Connectors IDC An Amp MTA 100 tool is used to insert the wires One 22 AWG red shell wire tail assembly is provided with each LumenDimM4micro Additional cable assemblies are available from RC4 The...
Page 6: ...e the SetAB button then release Func Several indicators will blink together to confirm that factory settings are restored NOTE This does NOT affect transmitter linking You must intentionally unlink to...
Page 7: ...g repeat the process until it stays off When the RF Connect LED is off the LumenDimM4micro is ready to be linked to your transmitter Link status is not affected by performing a Factory Reset You must...
Page 8: ...LumenDimIO Tap the Link button This button is recessed under the small slot to the right of the blue RF Connect LED Tap it with a small screwdriver or the end of a bent paperclip The blue RF Connect...
Page 9: ...to dimmer outputs to show you exactly what the dimmers are doing Setting the DMX Address Assigning DMX channels and dimmer curves is easy using RC4 OneTouch On your DMX lighting console bring up one d...
Page 10: ...You can use RC4 OneTouch with the SetCD button to set the second paid of dimmers to their own addresses For example if you want DimC to be set to DMX address 11 bring up 11 30 for the LED curve at the...
Page 11: ...ed and checked then apply power The LumenDimM4micro can control a variety of devices including solenoids relays servo motors and much more Power Input 6 35VDC Do not exceed voltage rating for connecte...
Page 12: ...de for Warm Cool White Control The LumenDimM4micro includes a color Cross Fade mode sometimes called X Fade Cross fading between warm and cool white light sources produces a range of color temperature...
Page 13: ...smooth 19 bit dimming default setting Choosing Other Dimmer Curves or Profiles The LumenDimM4micro default is the ISL dimmer curve which is best for LEDs This is also the curve that is selected with...
Page 14: ...mer the miniplug DMX port becomes an input when the device is not linked to a transmitter When using the LumenDimM4micro for cinema motion picture capture PWM frequencies can be adjusted for the smoot...
Page 15: ...ator Do not exceed the maximum total power handling of the LumenDimM4micro which is 6A That is 72W at 12V 144W at 24V shared across the four dimmer channels Always use a fuse or circuit breaker at the...
Page 16: ...rolina USA Local 44 0 20 3289 8765 London UK 1 866 237 6641 Toll Free Fax North America Email support theatrewireless com Website www rc4wireless com Knowledge Base http rc4 info We re here to help yo...