us before returning your instrument, as some difficulties can be easily solved on-site by the user. Please have the model 

and serial number of the unit handy when you contact us at 

[email protected]

.

There are no user-repairable parts of the logger. Any attempt at repair, whether successful or not, without prior 

authorization from RBR Ltd., will void the warranty. If it is necessary to return the product to RBR for an upgrade, repair, 

or calibration; please review the detailed shipping information on our website

 

www.rbr-global.com

 before returning the 

unit.

In the unlikely event of an instrument requiring service at RBR, contact us for an RMA number and please use the 
following shipping address:

RBR Ltd
95 Hines Road Unit 5
Kanata, Ontario
CANADA K2K 2M5

Tel1 (613) 599-8900

For those who are shipping from outside of Canada, you will need to clearly mark the waybill and any other customs 
paperwork with the following:

"Canadian goods being returned to manufacturer for repair. NOT A SALE."

Please state the instrument value on the waybill as closely as possible to the current market value based on the original 
purchase price less depreciation. Please contact RBR if you have any questions about the instrument value. Send the 
unit using your own preferred method (prepaid). However, we suggest that you do not use Ground Service since 
customs brokerage charges will be billed incorrectly.

Units repaired under warranty will be returned prepaid by RBR. Warranty repairs are decided on a case by case basis.

 

Standard Repair Charges (Non-warranty)

Our minimum repair charge is $150 CAD. This charge covers a comprehensive initial check, including verification 
calibration and sensor functionality. Minor repairs are also covered by this basic fee. If further repair work or re-
calibration is necessary, a quotation will be issued to the customer. Once we have received authorization to proceed, 
the repair shall be completed and the instrument returned as soon as possible. Please note that any units returned with 
low (or no) batteries will have new batteries installed and the costs will be added to the repair invoice.

6.4.4  Support kits

To simplify maintenance of your data logger, RBR sells support kits with enough O-rings, and silicone grease for 5 
deployments. Please contact RBR for more information or to place an order.

Summary of Contents for quartz3 BPR zero

Page 1: ...rbr global com INSTRUMENT GUIDE BPR zero...

Page 2: ...9 6 2 Changing the batteries RBRquartz BPR zero 11 6 2 1 Steps 11 6 3 Installing desiccant RBRquartz BPR zero 12 6 4 Maintenance and repairs 12 6 4 1 O rings RBRquartz BPR zero 12 Inspecting O rings 1...

Page 3: ...0008819revA 3 2 Introduction You can access the RBR instrument guide on the USB data stick provided when you purchase a logger from the Help menu in Ruskin and on the RBR web site at www rbr global c...

Page 4: ...RBR 0008819revA 4 3 Revision history Revision No Release Date Notes A 04 May 2020 Original...

Page 5: ...by us The liability of RBR Ltd extends only to the replacement cost of the instrument The customer will bear all costs of shipment to us for repair all other costs including return shipment will be b...

Page 6: ...rements are critical The RBRquartz BPR zero may be supplied with external power from RBRfermata power or RBRcervata power and memory canisters or cabled to an observatory for external power and realti...

Page 7: ...35 C The instrument has 8 X AA batteries installed however this is intended only for purposes of sustaining the instrument during external power interruptions of a few minutes While the Paros will con...

Page 8: ...2000 4000 7000 dbar Initial accuracy 0 01 FS full scale Resolution 10ppb at 16Hz sampling rate Accelerometer optional Range 3g Resolution 100ng The full mechanical drawing is available in Appendix A...

Page 9: ...shown below Only the battery end cap needs to be opened to access the data connector batteries desiccant and waste reservoir To open the logger battery end cap the two M6 screws will need to be remov...

Page 10: ...il the battery end cap is mated fully to the housing Remember to keep the O rings clean and avoid scratching the O ring mating surfaces Carefully inspect the O rings as described in the Inspecting the...

Page 11: ...ent during external power interruptions of a few minutes While the Paros will continue to run and be measured the valve will not operate 6 2 1 Steps Remove the battery end cap from the logger see Open...

Page 12: ...desiccant capsules can be opened the desiccant removed and replaced or dried 6 4 Maintenance and repairs 6 4 1 O rings RBRquartz BPR zero The single most important item of maintenance on any RBR subme...

Page 13: ...bishment please contact us for advice Replacing an O ring Lever the O ring from its groove Use a soft plastic or wood tool do not use a metal screwdriver or any other tool which may scratch the surfac...

Page 14: ...easure the pressure inside the housing of the instrument which is monitored by a barometer in order to correct for the drift of the sensors over time This actuation of this valve results in a small vo...

Page 15: ...towel around the reservoir in a clockwise manner when viewed as below The towel should only wrap around the reservoir once any additional layers will make it difficult to insert 8 While holding the to...

Page 16: ...closely as possible to the current market value based on the original purchase price less depreciation Please contact RBR if you have any questions about the instrument value Send the unit using your...

Page 17: ...RBR 0008819revA 17 7 Appendix 7 1 Appendix A RBRquartzBPR zero Product Drawing...

Page 18: ...RBR 0008819revA 18...

Page 19: ...RBR 0008819revA 19 7 2 Appendix B RBRquartzBPR zero Service Drawing...

Page 20: ...RBR 0008819revA 20 7 3 Appendix C RBRquartzBPR zero Connector Details...

Reviews: