12
1 - CODE REQUIREMENTS
1.1 - Regulations and
guidelines
- The installation must conform to the
requirements of the authority having
jurisdiction or, in the absence of such
requirements, to:
- the latest edition of the
National Fuel Gas
Code, ANSI Z223.1/NFPA 54
and or
CAN/
CSA B149.1, Natural Gas and Propane
Installation Code
.
- the latest edition of the
National Electric
Code ANSI/NFPA 70
and or
Canadian
Electrical Code Part 1 CSA C22.1
.
- Where required by the authority having
jurisdiction, the installation must conform
to the Standard for
Controls and Safety
Devices for Automatically Fired Boilers,
ANSI/ASME CSD-1
.
NOTICE!
Install CO detectors per local regulations.
NOTICE!
IB Boiler version meets the safety and other
performance requirements as specified in
ANSI Z21.13 standard.
NOTICE!
IW Water heater version meets the safety
and other performance requirements as
specified in ANSI Z21.10.3 standard.
NOTICE!
IB boiler version: per DOE mandate, the
operator control incorporates an automatic
means (outdoor reset) of adjusting the boiler
water temperature fot hot water heating. The
boiler must not operate without the automatic
means enabled.
NOTICE!
IB boiler version: in accordance with
Section 325 (f)(3) of the energy policy and
conservation Act, this boiler is equipped with
a feature that saves energy by reducing the
boiler water temperature has the heating load
decreases.
Summary of Contents for Infinity Energy 2
Page 3: ...3 SAFETY INSTRUCTIONS...
Page 5: ...5 SAFETY INSTRUCTIONS...
Page 132: ...132 17 MAINTENANCE...
Page 136: ...136 19 SPARE PARTS Spare parts...
Page 139: ...139 19 SPARE PARTS 50 48 50 49 53 56 57 55 54 58 47 52 48 52 51 55 52 020010 03 006 199...
Page 162: ...162 22 SEQUENCE OF OPERATION for BOILER...
Page 163: ...163 23 SEQUENCE OF OPERATION for WATER HEATER...